background image

LTE Industrial Router

SmartFlex SR305

USER MANUAL

Summary of Contents for SmartFlex SR305

Page 1: ...LTE Industrial Router SmartFlex SR305 USER MANUAL ...

Page 2: ...ctronic or mechanical including photography recording or any information storage and retrieval system without written consent Information in this manual is subject to change without notice and does not represent a commitment on the part of Advantech B B SmartWorx Advantech B B SmartWorx s r o shall not be liable for incidental or consequential damages resulting from the furnishing performance or u...

Page 3: ...fic situations Information notice Useful tips or information of special interest GPL licence Source codes under GPL licence are available free of charge by sending an email to cellularsales advantech bb com Advantech B B SmartWorx s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Manual Rev 1 released in the Czech Republic January 25 2017 i ...

Page 4: ...ndations 16 5 6 Removal of the DIN rail 17 5 7 Description of the rear panel 18 5 8 Description of the front panel 18 5 8 1 Status indication 19 5 8 2 Power connector PWR 20 5 8 3 Antenna connector ANT DIV GPS and WiFi 21 5 8 4 SIM card reader 22 5 8 5 MicroSD card reader 22 5 8 6 Ethernet Ports ETH0 and ETH1 23 5 8 7 Power over Ethernet PoE 24 5 8 8 USB Port 26 5 8 9 I O Port 26 5 8 10 Reset 29 5...

Page 5: ...rameters of cellular module 42 7 5 Technical parameters of GNSS 43 7 6 Technical parameters of WiFi 43 7 7 Technical parameters of I O port 44 7 8 Technical Parameters of Power over Ethernet PoE 44 7 9 Other Technical Parameters 45 8 Recommended Literature 46 9 Troubleshooting 47 9 1 FAQ 47 10 Customers Support 49 10 1 Customer Support for NAM 49 10 2 Customer Support for Europe 49 10 3 Customer S...

Page 6: ...6 Version RS232 RS485 metal 12 17 Ver RS232 RS485 with WiFi metal 12 18 Version RS232 RS485 ETH metal 12 19 RS232 RS485 ETH WiFi plastic 13 20 RS232 RS485 ETH WiFi metal 13 21 Label examples 13 22 Basic dimensions of the router box 16 23 Default position of DIN holder 17 24 Removal of the DIN rail 17 25 SmartFlex front panel 18 26 Power connector 20 27 Connection of power supply 20 28 Connecting t...

Page 7: ...mpers 32 44 Version with SWITCH board 33 45 Version with RS232 RS485 ETH interface 34 46 Ethernet connector 35 47 RS485 connector 35 48 RS232 connector 35 49 Router connection 37 50 Entering the IP address of the router 38 51 Entering login information 38 52 Router web interface 39 v ...

Page 8: ...of RS485 connector 31 19 Connection of RS422 connector 32 20 Technical specification of RS232 and RS485 33 21 State indication of the SWITCH interface 33 22 SWITCH interface parameters 34 23 Connections of the Ethernet Connector 34 24 Connections of Terminal Block Connector RS485 35 25 Connections of Terminal Block Connector RS232 35 26 State indication of the RS232 RS485 ETH interface 36 27 Techn...

Page 9: ...conditions Protect the router against dust moisture and high temperature The router should not be used in locations where flammable and explosive materials are present including gas stations chemical plants or locations in which explosives are used We remind users of the duty to observe the restrictions concerning the utilization of radio devices at such places Switch off the router when travellin...

Page 10: ... exempt RSS standard s Operation is subject to the following 2 conditions 1 this device may not cause interference and 2 this device must accept any interference including interference that may cause undesired operation of the device This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to prov...

Page 11: ...uthority to operate the product This product has demonstrated EMC compliance under conditions that included the use of compliant peripheral devices and shielded cables between system components It is important that you use compliant peripheral devices and shielded cables between system components to reduce the possibility of causing interference to radios televisions and other electronic devices 4...

Page 12: ...ther devices via Ethernet The SmartFlex can also be configured with a wide variety of port options Options include SWITCH three switched Ethernet ports RS232 RS485 422 combination of serial interfaces RS232 RS485 ETH combination of serial interfaces and an Ethernet port with higher insulation The router can be supplied in either plastic or metal casing depending on customer requirements The router...

Page 13: ...eet management security systems telematic telemetric remote monitoring vending and dispatcher machines 3 1 Usage of the Router The router is primarily intended for these four basic situations I Access to the Internet from LAN Figure 1 Access to the Internet from LAN 6 ...

Page 14: ...SmartFlex SR305 II Backed up access to the Internet from LAN Figure 2 Backed up access to the Internet III Secure networks interconnection or using VPN Figure 3 Using a VPN tunnel 7 ...

Page 15: ...SmartFlex SR305 IV Serial Gateway Figure 4 Serial Gateway 8 ...

Page 16: ...n I O connector 8 pins1 4 pin and 5 pin terminal block for RS485 and RS232 only for version with interface RS232 RS485 422 3 pin and 4 pin terminal block for RS485 and RS232 only for version with interface RS232 RS485 ETH DIN rail clip Start guide for SmartFlex routers 1 These pins are designed for cables with diameters from 0 2 to 0 8 mm2 9 ...

Page 17: ...sic package LTE antennas Terminal antenna Taoglas TG 30 8113 order code BB TG 30 8113 WiFi antenna Sectron order code BB AW A2458G FSRPK Power supplies Regular power supply with universal set of power cords order code BB RPS v3 MO2 M Power supply for use with PoE PSE versions with US power cord order codes BB RPS v3 PSE and BB PWRCORD US 10 ...

Page 18: ...BOUT USB SD ETH WiFi 232 485 SM IP Basic version 2 x 2 x 1 x 1 x 1 x 2 x Basic version with WiFi 2 x 2 x 1 x 1 x 1 x 2 x 1 x Version with SWITCH board 2 x 2 x 1 x 1 x 1 x 5 x Version with SWITCH board WiFi 2 x 2 x 1 x 1 x 1 x 5 x 1 x Version with RS232 RS485 422 board 2 x 2 x 1 x 1 x 1 x 2 x 1 x 1 x Version with RS232 RS485 422 WiFi 2 x 2 x 1 x 1 x 1 x 2 x 1 x 1 x 1 x Version with RS232 RS485 ETH ...

Page 19: ...rsion RS232 RS485 plastic Figure 12 Ver RS232 RS485 with WiFi plastic Figure 13 Version RS232 RS485 ETH plastic Figure 14 Version SWITCH metal Figure 15 Version SWITCH with WiFi metal Figure 16 Version RS232 RS485 metal Figure 17 Ver RS232 RS485 with WiFi metal Figure 18 Version RS232 RS485 ETH metal 12 ...

Page 20: ...RS485 ETH WiFi plastic Figure 20 RS232 RS485 ETH WiFi metal 5 2 Delivery identification Trade name Type name Other SmartFlex SR305 SmartFlex Router in a plastic or metal box Table 2 Delivery identification Figure 21 Label examples 13 ...

Page 21: ...e for NAM 2x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader RS232 RS485 SR305 SR3051x3y0 LTE module for NAM 2x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader WiFi RS232 RS485 SR305 SR3050x4y0 LTE module for NAM 3x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader RS232 RS485 SR305 SR3051x4y0 LTE module for NAM 3x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader WiFi RS23...

Page 22: ...x Examples of complete order codes Order code Features interfaces Box Power supply SR30500010 LTE module for NAM 2x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader plastic None SR30510120 LTE module for NAM 5x ETH 1x USB 2x BI 1x BO 1x microSD reader 2x SIM reader WiFi metal None Table 6 Examples of order code 15 ...

Page 23: ...er which there is no need to have examination immunity or issues in connection with EMC according to EN 61439 1 2011 Attention If the negative pole of the router is grounded there is no protection against reversed polarity In compliance with the EN 61439 1 2011 specification it is necessary to observe the following assembly instructions for a router attached to a switchboard For whip antennas it i...

Page 24: ...an earth bonding distribution frame for the grounding of the power supply of the router data cables and antenna within the switchboard 5 6 Removal of the DIN rail The DIN holder is suitable for a DIN rail according to EN 60715 standard only The default position of of plastic or metal holder which is used for mounting the router on a DIN rail is shown in the following figure Figure 23 Default posit...

Page 25: ...he computer network PoE only for PoE PSE or PoE PD versions ETH1 RJ45 Connector for connection into the computer network PoE only for PoE PSE or PoE PD versions ANT SMA Connector for main antenna DIV SMA Connector for diversity antenna GPS SMA Connector for GPS antenna WiFi R SMA Connector for WiFi antenna only for versions with WiFi module USB USB A 2 0 Host Connector for connection of USB device...

Page 26: ...r one sec LED goes out 1x per two sec LED goes out 1x per five sec Signal strength is from 50 dBm to 69 dBm Signal strength is from 70 dBm to 89 dBm or differ ence between neighbouring cells is exactly 3 dBm Signal strength is from 90 dBm to 113 dBm or differ ence between neighbouring cells is smaller than 3 dBm DAT Red Blinking Communication in progress on radio channel IN0 Green On Binary input ...

Page 27: ...rsed polarity without signaling is built into the router Note The protection against reversed polarity is lost if the negative pole is grounded The router can be put into low power mode using a special command lpm It can then be awakened for example by an activity on binary input or using an internal timer Circuit example Figure 27 Connection of power supply Note for PoE See Chapter 5 8 7 for info...

Page 28: ...a connector DIV is used The third connector GPS is intended for a GPS antenna the router supports active GPS antennas An R SMA connector named WiFi is designed for the connection of a WiFi antenna available only for versions with a WiFi module The router can not operate without a main antenna connected through the port marked as ANT An SMA connector is used for the connection of the antenna The an...

Page 29: ...slot until you hear a click After hearing this click release the card and it will pop out of its slot Remove the SIM card and push any other SIM card into the slot until it clicks into place Figure 29 SIM cards 5 8 5 MicroSD card reader The microSD card reader is located on the rear panel of the router the third slot This card reader allows the router to operate with microSD memory cards The techn...

Page 30: ...gure 30 MicroSD card 5 8 6 Ethernet Ports ETH0 and ETH1 Panel socket RJ45 Pin Signal mark Description Data flow direction 1 TXD Transmit Data positive pole Input Output 2 TXD Transmit Data negative pole Input Output 3 RXD Receive Data positive pole Input Output 4 DC PoE power if it s equipped by PoE 5 DC PoE power if it s equipped by PoE 6 RXD Receive Data negative pole Input Output 7 DC PoE power...

Page 31: ... Router Insul Strength between Ports Without PoE 1 5 kV 1 5 kV PoE PD 1 5 kV none PoE PSE none none Table 12 Insulation strength of Ethernet ports 5 8 7 Power over Ethernet PoE On the router models with PoE the PoE standard IEEE 802 3at 2009 and PoE standard IEEE 802 3af 2003 are supported in both Ethernet ports ETH0 ETH1 The PoE PD version allows the router to be powered over the Ethernet by anot...

Page 32: ...lass 4 in both Ethernet ports ETH0 and ETH1 The PoE PSE parameters can be found in Chapter 7 8 The PoE state is indicated by the POE LED on the front panel of the router see Chap 5 8 1 When sufficient voltage 44 to 57 V and power is available is indicated by the green light A yellow POE LED indicates insufficient power or voltage through the PWR connector When a device is being powered from the ro...

Page 33: ... Signal mark Description 1 IN0 Binary input 0 2 IN0 Binary input 0 3 IN1 Binary input 1 4 IN1 Binary input 1 5 OUT Binary output 6 OUT Binary output Table 14 Connection of I O port Figure 36 I O connector The I O user Interface is designed for the processing of binary input and control setting of binary output Binary output is open in the default configuration The isolation strength is 1 5 kV The ...

Page 34: ...rface status log 1 max 3 V 0 4 mA Off log 0 min 5 V 0 7 mA On log 0 type 12 V 2 mA On log 0 max 60 V 7 mA On Table 15 Characteristics of inputs The binary input status in the Shell is returned via io get bin0 or io get bin1 Binary inputs connection example Figure 37 Binary inputs connection 27 ...

Page 35: ...05 Binary output Binary output parameters 60 V AC 300 mA 60 V DC 300 mA The current of the binary output is limited by a resettable fuse 300 mA Binary output connection example Figure 38 Binary output connection 28 ...

Page 36: ...r small tool Figure 39 Router reset Before resetting the router it is recommended to back up the router configuration set tings see Configuration manual because resetting the router will return all configuration settings to their default states It is important to distinguish between the router reset and reboot Action Router behavior Invoking events Reboot Turns off and then turns on the router Dis...

Page 37: ... 9 Interfaces Description Besides the basic version of the SmartFlex router there are other versions available with one of the following interfaces RS232 RS485 422 interface SWITCH interface RS232 RS485 ETH interface 30 ...

Page 38: ...ure 40 Version with RS232 RS485 422 interface Connection of RS232 connector Pin Signal Description Direction 1 CTS Clear To Send Output 2 RTS Request To Send Input 3 GND Signal ground 4 RXD Receive Data Input 5 TXD Transmit Data Output Table 17 Connection of RS232 connector Both connectors RS232 and RS485 422 have a common ground connection Figure 41 RS232 connector Connection of RS485 connector P...

Page 39: ...nnector Figure 42 RS485 422 connector The selection of either RS485 or RS422 can be performed by using jumpers on the board The points where jumpers have to be mounted are shown on the port see figure below Three jumpers are required for the RS485 interface or one jumper for the RS422 interface The default configuration is RS485 with termination off Figure 43 Connection of jumpers 32 ...

Page 40: ...er reads Ethernet frames data packets on an Ethernet link from any port on the SWITCH interface and transmits them on other ports of the SWITCH interface Each port can transmit frames inde pendently on the other ports State indication is displayed separately on each connector These router versions comply with the standards and temperature ranges stated in Chap 7 1 except for having a lower maximum...

Page 41: ...between the ETH2 and RS485 interfaces and from the rest of the router too The RS232 interface is not insulated from the rest of the router State indication is displayed by LEDs above each connector as shown in the table below These router versions comply with the standards and temperature ranges stated in Chap 7 1 Figure 45 Version with RS232 RS485 ETH interface Connection of ETH connector Pin Sig...

Page 42: ... Connections of Terminal Block Connector RS485 Signal ground is isolated from the router s ground Figure 47 RS485 connector Connection of RS232 connector Pin Signal Description Direction 1 AUX 5 V 500 mA 2 GND Signal ground 3 RXD Receive Data Input 4 TXD Transmit Data Output Table 25 Connections of Terminal Block Connector RS232 Common with router s signal ground Figure 48 RS232 connector 35 ...

Page 43: ...2 yellow LED Indicates Transmit data Table 26 State indication of the RS232 RS485 ETH interface Technical specification of RS232 and RS485 bus EN 1434 and Ethernet IEEE 802 3 ETH2 RS485 and RS232 interface Max operating RS232 bus current 15 mA Max number of devices on RS485 bus each 1 5 mA 256 Max data rate 230400 bit s on RS232 38400 bit s on RS485 100 Mbit s on ETH2 Max total cable length 300 Bd...

Page 44: ...peration it is necessary to connect all of the components that are required to run your applications Don t forget to insert a SIM card The router can not operate without a connected antenna SIM card and power supply If the antenna is not connected the router may be damaged Figure 49 Router connection 37 ...

Page 45: ...in the router it is not possible for the router to operate Any inserted SIM card must have active data transmission 6 3 1 Configuration by web browser For status monitoring configuration and administration of the router a web interface is available which can be accessed by entering the IP address of the router into the web browser The default IP address of the router is 192 168 1 1 Attention it is...

Page 46: ...n information the user will have access to the router web interface via their browser Figure 52 Router web interface A detailed description of the router settings in the Web interface can be found in the Configuration manual for SmartFlex routers 39 ...

Page 47: ...diately Humidity Operating Storage 0 to 95 relative humidity non condensing 0 to 95 relative humidity non condensing Altitude Operating 2000 m 70 kPa Degree of protection IP30 Supply voltage 10 to 60 V DC Consumption Idle Average Peak Sleep mode 2 5 W 4 W 11 W 10 mW Dimensions 55 x 97 x 125 mm DIN 35 mm EN 60715 Weight Plastic box Metal box approximately 170 g depends on interface approximately 37...

Page 48: ...t A 8 kV crit A RF field AM modulated IEC 61000 4 3 Enclosure 20 V m crit A 80 2700 MHz Fast transient EN 61000 4 4 Signal ports Power ports Ethernet ports 2 kV crit A 2 kV crit A 2 kV crit A Surge EN 61000 4 5 Ethernet ports Power ports I O ports 2 kV crit B shielded cab 0 5 kV crit B 1 kV L to L crit A 2 kV L to GND crit A RF conducted EN 61000 4 6 All ports 10 V m crit A 0 15 80 MHz Radiated em...

Page 49: ...ompression 3GPP TS25 212 Supported frequencies 850 BdV AWS BdIV 1900 MHz BdII UMTS features PS bit rate 384 kbit s DL 384 kbit s UL Output power Class 3 24 dBm 1 3 dB Supported frequencies 850 BdV AWS BdIV 1900 MHz BdII GPRS EDGE features Bit rate 237 kbit s DL 59 2 kbit s UL GPRS multislot class 12 CS 1 to 4 EDGE multislot class 12 CS 1 to 4 MCS 1 to 9 Supported frequencies 850 900 1800 1900 MHz ...

Page 50: ...ng sensitivity is the lowest GNSS signal level for which the device can still detect an in view satellite 98 of the time when in sequential tracking mode Acquisition sensitivity is the lowest GNSS signal level for which the device can still detect an in view satellite 50 of the time 7 6 Technical parameters of WiFi WiFi Antenna connector R SMA 50 Ohms Supported WiFi band 2 4 GHz 5 Ghz Standards 80...

Page 51: ...inary output parameters 60 V AC 300 mA 60 V DC 300 mA 7 8 Technical Parameters of Power over Ethernet PoE Standards IEEE 802 3at 2009 PoE and IEEE 802 3af 2003 PoE are supported Ca bling needed is Category 5 up to 12 5 Ω It is possible to use a passive PoE injector PoE PD parameters for opposite PSE Input voltage range 42 5 57 V Power available 25 50 W Maximum current 600 mA Table 35 PoE PD parame...

Page 52: ...SmartFlex SR305 7 9 Other Technical Parameters Other technical parameters CPU power 2 DMIPS per MHz Flash memory 256 MB RAM 512 MB M RAM 128 kB Table 37 Other technical parameters 45 ...

Page 53: ...SmartFlex SR305 8 Recommended Literature 1 Advantech B B SmartWorx Start Guide for SmartFlex 2 Advantech B B SmartWorx Configuration Manual for SmartFlex Routers 46 ...

Page 54: ...supply I can t access the Web server over NAT The remote HTTP access of the router has to be disabled the default server ad dress has to be your web server and the gateway of the web server has to be the IP of the router Mobile WAN connection fails DAT LED off Check the signal power If the signal power is weak you will have to use a better antenna If the neighboring cells have a similar signal str...

Page 55: ...er s address it is impossible to connect to the dyndns org server The following mes sages will be shown in the system log DynDNS daemon started Error resolving hostname no such file or directory Connect to DynDNS server failed L2TP or IPSec isn t establishing Check the system log for error messages I switched the router to offline mode by SMS message but the router is in online mode after restart ...

Page 56: ...rd must be handled carefully as with a credit card Don t bend don t scratch on this and do not expose to static electricity During cleaning of the router do not use aggressive chemicals solvents and abrasive cleaners Advantech B B SmartWorx Company hereby declares that the router narrated in this user s guide fits all basic demands of directive 1999 5 EC R TTE Router fits values of coefficient SAR...

Reviews: