OPERATION MANUAL

Technical changes reserved
0141 0316-212   20.07.2020

Rain Detector REGME

model 12 V AC/DC or 24 V AC/DC

screws and cable gland properly tightened, and the covergasket should 

always be available on the sensor cover !

•  The suitability for certain applications is to be checked by the user

Settings

Signal generator output (optional)

At the connection terminals (Pin BUZ and GND) a passive Piezo signal gene-

rator can be connected. The condition of signal (acustic signal for dry or wet) 

can be selected with the plug links S1-S2 or S2-S3. In the default-position 

S2-S3, the signal generator is inactive for rain.

Switching mode

The switching mode of the relay (pickup or dropout with rain) can be

selected with the plug links T1-T2 or T2-T3. In the factory settings, link T1-T2 

is connected and the relay closes if the sensor surface gets wet.

Heating

The sensor surface is heated, if the link of HZ1-HZ2 is connected. To

ensure faster drying and for operation below freezing point, the heater should 

be switched on. For sensing fog, the heater can be switched off.

Automatic heating

The heating is only switched on when the sensor surface is wet. 

Sensitivity setting

The sensitivity for detecting rain can be adjusted with the potentiometer 

„SENS“. Rotating the potentiometer clockwise results a higher sensitivity. 

For detecting rain mostly the middle position of the potentiometer is suitable. 

Please note that no function takes place in the end position!

Relay time delay

As soon as rain is detected and the relay has been switched (on or off, 

depending on the jumper setting), it is switched back to the starting positi-

on with a time delay. The time during which the relay is switched on or off 

(depending on the jumper setting) can be set from approx. 90 to 330 seconds 

using the „TIME“ potentiometer. If rain is detected again while the time delay 

is active, it starts again.

Indicators

There is a green LED on the device to indicate the operation status and a red 

LED to indicate the switch position (meansrelay contact closed).

Maintenance

The Rain Sensor unit is almost maintenance free. The sensor surface

must be occasionally cleaned with a moist cloth ( e.g. once annually,

depending on the place of installation). In case of persistent condition, even if 
it does not rain, it triggers due to strong contamination.

Connection Layout

REL NC 

Opening switch contact

REL NO 

Closing switch contact

REL CO 

Common switch contact

AC/DC 

Operating voltage AC or 24 V DC +10%

AC/GND 

Operating voltage AC or 0 V

Plug Links Configuration

Switch mode signal generator (dry)

Common contact to S3 and S1

Switch mode signal generator (wet)

Signal generator ground

Signal generator output

Switch mode relay (dry)

7

Common contact to T3 and T1

Switch mode relay (wet)

Heating

10

Heating

11-16 not occupied

Dimensions

Accessoires

wall / mast mounting bracket
including mouting hardware

Attention

Please avoid extreme mechanical and inappropriate exposure.
The device/product is not suitable for potential explosive areas and medical-
technical applications.