Master-Slave Operation:
This function will allows you to link units together to run in a Master-Slave
mode. In Master-Slave operation one unit will act as the controlling unit and
the others will react to the controlling units built-in programs. Any unit can act
as a Master or as a Slave however, only one unit can be programmed to act
as the “Master.”
Master-Slave Connections and Settings:
1. Daisy chain your units via the XLR connector on the rear of the unit. Use
standard XLR microphone cables to link your units together. Remember that
the Male XLR connector is the input and the Female XLR connector is the
output. The first unit in the chain (master) will use the female XLR connector
only. The last unit in the chain will use the male XLR connector only.
2. Using the Master unit, choose your desired mode of operation and
connect the “Slave” unit or units.
3. Set all the dipswitces on the “Slave” unit(s) to the “Off” position. The
“Slave” unit(s) will now follow the “Master” unit.
TROUBLESHOOTING
Listed below are a few common problems the user may encounter, with
solutions.
Unit not responding to DMX:
1. Check that the DMX cables are connected properly and are wired
correctly (pin 3 is “hot”; on some other DMX devices pin 2 may be ‘hot’).
Also, check that all cables are connected to the right connectors; it does
matter which way the inputs and outputs are connected.
Unit does not respond to sound:
1. Quiet or high pitched sounds will not activate the unit.
If problems are not resolved; Contact AZTEC-ELECTRONICS
DISTRIBUTOR & DEALERS for service.
www.aztec-electronic.com
/
www.aztec-electronics.com
/
Summary of Contents for LED PAR-48 RGBW
Page 1: ...USER INSTRUCTION MANUAL ...