Azbil ACTIVAL+ FVY513E Series Specifications & Instructions Download Page 4

AB-7131 

 

Options 

Separately order the following optional parts if needed. 

Item Specification 

Note 

Seal connector 

Part No. 
83104346-003 

7 mm to 

9 mm 

Seal connector is necessary for IEC IP54 

protection.

 

Part No. 
83104346-004 

9 mm to 

11 mm 

Part No. 
83104346-005 

11 mm to 

13 mm 

Part No. 
83104098-001 
(for Insertion-type 
pipe temperature 
sensor) 

4 mm to 

6 mm 

Seal connector for 
the cable gland 

Part No. 
83104346-012 

6 mm to 

8 mm 

Seal connector for SAnet cable gland 

with three ports is necessary for IEC 

IP54 protection.

 

Part No. 
83104346-013 

7 mm to 

9 mm 

Part No. 
83104346-014 

9 mm to 

11 mm 

Part No. 
83104346-015 

11 mm to 

13 mm 

Display Panel  Model QY5010S1000* 

Data displaying device  
for Model FVY513EJ/FVY514EJ series 

For the specifications of Display Panel, 
refer to 

AB-7043 Specifications/ 

Instructions of Display Panel

Temperature sensor 
for pipe surface 
(Pipe sensor) 

Model TY7820Z0P01  Total length: 1.5 m 

For the specifications of the pipe sensor, 
refer to 

AB-6923 Specifications/ 

Instructions of Temperature Sensor for 
Pipe Surface

Model TY7820Z0P05  Total length: 5 m 
Model TY7820Z0P10  Total length: 10 m 
Model TY7820Z0P30  Total length: 30 m 

Insertion-type pipe temperature sensor  
Model TY783 

For the specifications of the insertion type pipe temperature sensor, refer to 

AB-5429 

Specifications/Instructions of Pipe Temperature Sensor

Outdoor cover  Part No. DY3001A1017 

Required when the product is installed outdoors. 

Cable gland with three ports 
Part No. DY7000A1000 

Do not use it outdoors. 
For the specifications of the cable gland with three ports, refer to 

AS-923E Specifications of 

Cable Gland with Three Ports

RS-485/analog output signal converter 
Model RYY792C3001 

Signal converter from RS-485 to 4-20 mA DC 
(Two channels of analog output per one converter) 

For the specifications of RS-485/analog 
output signal converter, refer to 

AB-7045 

Specifications/Instructions of RS-485/ 
Analog Output Signal Converter

Note: 
  *  Order Display Panel (Model QY5010S1000) and connect it to Model FVY513EJ/FVY514EJ. Display Panel is required to set the product. 

 

 

 

 

Summary of Contents for ACTIVAL+ FVY513E Series

Page 1: ...Infilex AC Model WY5117 Flow data stored in Model FVY513EJ FVY514EJ is retrieved via RS 485 communication Modbus protocol The retrieved flow data is effective for energy saving facility operation JIS...

Page 2: ...Do not freeze this product Doing so may damage the valve body and cause leakage When piping this product be sure there is no foreign matter in the pipes If foreign matter remains in the pipes the prod...

Page 3: ...control the quality of process fluid water and do not allow rust or foreign object inside the valve Rust or foreign object inside the valve lowers flow rate measuring accuracy Thermally insulate the v...

Page 4: ...ns of the pipe sensor refer to AB 6923 Specifications Instructions of Temperature Sensor for Pipe Surface Model TY7820Z0P05 Total length 5 m Model TY7820Z0P10 Total length 10 m Model TY7820Z0P30 Total...

Page 5: ...End connection JIS 20K flanged end raised flange Size Cv Close off rating Model number Nominal size Cv Close off ratings FVY513EJ0012 FVY514EJ0012 DN15 1 2 2 5 1 0 MPa FVY513EJ0013 FVY514EJ0013 DN15...

Page 6: ...ion 6 pin 3 pin 2 connector Display Panel 4 pin connector Enclosure rating IEC IP54 dust proof and splash proof Operation status indicator LED 1 red LED Status LED indication Normal Repetition of 1 se...

Page 7: ...FVY513EJ0081 FVY514EJ0081 DN80 3 125 1250 l min Measuring accuracy Factory preset Notes 1 The flow measurement accuracy figures assume a temperature range of 7 17 C or 45 65 C internal pipe pressure...

Page 8: ...racy and the error due to wiring length 7 Energy calculation accuracy is calculated from the flow rate measuring accuracy at 1 C measuring error of the temperature difference 8 The flow rate measuring...

Page 9: ...f the product relay terminal block wiring and the relay terminal block load device in connection 2 JCS Japanese Electric Wire and Cable Makes Association 3 KPEV Wire standard provided by Furukawa Elec...

Page 10: ...water temperature Reset switch Connector for Display Panel 24 V AC Power Port for Display Panel cable Port for temperature sensor Pt100 input cable Port for valve sensor cable Port for temperature se...

Page 11: ...side of the valve For chilled hot water 40 or more meshes If the strainer cannot be installed just before the inlet of each valve install it on the pipe diverting sections for each piping system Insta...

Page 12: ...or faces downward Flow direction Flow direction Flow direction Figure 5 Incorrect mounting orientations Piping CAUTION When installing this product hold it in the proper position and securely fasten i...

Page 13: ...oduct Heat insulating Apply heat insulation as illustrated by in Fig 6 If the yoke and or the actuator are covered with insulation material the point cannot be checked or may be distorted If the heat...

Page 14: ...ve the actuator may break down Do not manually open or close the valve more than 100 or less than 0 scale 1 Turn off the power 2 Hold the joint using a wrench etc gently turn the wrench to the desired...

Page 15: ...it may not make proper contact Use crimp terminals with insulation for connections to the product terminals Failure to do so may cause short circuit leading to fire or device failure Tighten the term...

Page 16: ...sor Pt100 input Terminal Wire color Description Temperature sensor for pipe surface Insertion type pipe temperature sensor T1A Red Red Pt100 A supply water temperature T1B White Black Pt100 B supply w...

Page 17: ...the recommended cable 1 Pass the 4 core cable of Display Panel through the actuator port for Display Panel See Fig 3 for the location of the port 2 Strip the wire sheath Strip length is 8 mm See Fig...

Page 18: ...pply cable Attach the optional cable gland with three ports Model DY7000A1000 to the wiring port to share the wiring port with signal lines Connect the wires of RS 485 communication cable to the conne...

Page 19: ...with multiple 4 20 mA input type products See Figs 23 and 24 4 20 mA control signal input is not isolated from the power and the 4 20 mA input impedance is 282 For connecting a controller the relatio...

Page 20: ...Terminals 2 6 and 8 of the product are internally connected 3 Refer to 6 Single transformer with two products in the Precautions for connection section Figure 24 Connection example Two Model FVY513EJ...

Page 21: ...izing pulse output open collector output Model FVY51XEJ This product 3 4 V Protection diode Magnetic counter 0 V Figure 29 Connection example Magnetic counter with relay coil Master Slave Model R seri...

Page 22: ...y release all the latches start with the one which cannot be visibly checked 1 Press the upper part of one of the male latches 1 in the figure below 2 Press up the lower part of the one of the male la...

Page 23: ...port 3 Connect the seal connectors optional to the cover of the cable gland IMPORTANT When tightening a seal connector to the cover be sure not to press excessive force on the latches Figure 32 Connec...

Page 24: ...without insulation sleeve is crimped on a wire end use a tube marker for safety During wire termination do not allow any foreign objects including chips and stripped insulation to get inside the prod...

Page 25: ...h the base of the cable gland from the wiring port of the product IMPORTANT Carefully handle the O rings attached to the cable gland Check that the cable gland has 3 O rings and be sure to keep these...

Page 26: ...Visual inspection Semiannual Fluid leakage from the gland and the flange face Loosened bolts Valve and actuator damages Operating status Semiannual Unstable open close operation Abnormal noise and vi...

Page 27: ...he valve position detecting accuracy Disposal Dispose of this product as industrial waste in accordance with your local regulations Do not reuse all or any part of the product 1 cm Lower setscrew of t...

Page 28: ...na Fujisawa Kanagawa 251 8522 JAPAN https www azbil com Rev 6 0 Apr 2020 AB 7131 J AI 7131 Rev 4 0 28 ACTIVAL and ACTIVAL are trademarks of Azbil Corporation in Japan or in other countries This produc...

Reviews: