background image

2

The meter is pre-set to measure
objects with an emissivity of 0.95. 
This will accommodate the majority
of items measured without 
compensating for higher or lower 
value. In most cases there will be 
little difference in measurements ,
even if an object's emissivity is 
higher or lower than this pre-set 
value. Compare and confirm with 
known values if in doubt.

 FRONT PANEL DESCRIPTION 

                  

1. 

IR sensor                                   

2. 

LCD Display                           

3. 

Measure  key

4. 

Battery  

     compartment

    (rear side)

5. Laser 

 INDICATOR 

1. 

Digital readout

o

2.

  C .   Celsius

o

3.

  F .    Fahrenheit

4.

 BAT.  Battery indicator.

5.      

.

    

Laser on annunciator.

C

o

o

F

BAT

1

3

4

2

5

5

2

3

4

8878

1

Summary of Contents for 8878

Page 1: ...Model 8878 STICK INFRARED THERMOMETER OPERATION MANUAL 8879...

Page 2: ...imple one hand operation time saving to the temperature measurement Be sure the measured object fills the spot seen by the aperture There will be a delay of approximately one second between the time y...

Page 3: ...le difference in measurements even if an object s emissivity is higher or lower than this pre set value Compare and confirm with known values if in doubt FRONT PANEL DESCRIPTION 1 IR sensor 2 LCD Disp...

Page 4: ...rformance standrad 21CFR Sub chapter J is CLASS II laser product less than 1mini walt output at 675nm wavelength Indicates the use of laser equipment and the category of laser used LASER SPLASH LASER...

Page 5: ...wer off Operating Temperature Operating Humidity Power Supply Power Current Weight Size LCD display o 4 C to 600 F 20 to 320 C o o 1 sec Approx Automatic shut off after 4 seconds 0 C to 50 C 32 F to 1...

Page 6: ...re necessary to freeze the displayed reading C MEASUREMENT CONSIDERA TIONS Holding the meter by its handle point the IR Sensor toward the object whose temperature is to be measured The meter automatic...

Page 7: ...d tight contact at the battery clip Ensure the unit is at the specified operating temperature Constant or spurious over load OL display Check battery voltage Check for electromagnetic interference EMI...

Page 8: ...compressed air to remove any particles on the lens if the contamination can not be removed with air use a soft cotton swab Any swab should be slightly damp and very light pressure should be applied t...

Page 9: ...amage resulting from leaking batteries Proof of purchase is required for warranty repairs Warranty is void if the meter has been opened RETURN AUTHORIZATION Authorization must be obtained from the sup...

Page 10: ...55022 EN 50082 1 1997 EN 55024 EN 61000 4 2 3 8 ENV 50204 the meter complies with the essential protection requirements of Council Directive 89 336 EEC on the approximation of the laws of the Member S...

Page 11: ...ter Anemometer Sound Level Meter Air Flow meter Infrared Thermometer K type Thermometer K J T type Thermometer K J T R S E type Thermometer pH Meter Conductivity Meter T D S Meter D O Meter Saccharime...