Optimization and
Customization
While the Ayre QA-9 A/D is typically configured
with your recording software via the USB
connection, the AES/EBU settings and other options
are configured with small toggle switches accessible
on the rear of the unit.
AES/EBU Sample Rate
The AES/EBU output sample rate can be configured
as detailed in the table below:
4x/1x
2x/1x
48/44
Sample Rate
Down
Down
Down
44.1 kHz
Down
Down
Up
48.0 kHz
Down
Up
Down
88.2 kHz
Down
Up
Up
96.0 kHz
Up
Don’t Care
Down
176 kHz
Up
Don’t Care
Up
192 kHz
The AES/EBU output is only active
when there is no USB connection.