background image

218-232 Show 15
233-247 Show 16
248-255 Sound active running show 1 to 16

3CH mode:

CH1 

000-255

Red

CH2

000-255

Green

CH3

000-255

Blue

5CH Mode:

CH1 

000-255

The 1

st

 head Color

CH2

000-255

The 2

nd

 head Color

CH3

000-255

The 3

rd

 head Color

CH4

000-255

The 4

th

 head Color

CH5

000-255

The 5

th

 head Color

7CH Mode:

CH1 

000-255

The 1

st

 head Color

CH2

000-255

The 2

nd

 head Color

CH3

000-255

The 3

rd

 head Color

CH4

000-255

The 4

th

 head Color

CH5

000-255

The 5

th

 head Color

CH6

000-255

Dimmer

CH7

000-255

Strobe

15CH Mode:

CH1,CH4,CH7,CH10,CH13

000-255

Red 1/2/3/4/5

CH2,CH5,CH8,CH11,CH14

000-255

Green 1/2/3/4/5

CH3,CH6,CH9,CH12,CH15

000-255

Blue 1/2/3/4/5

18CH Mode:

CH1,CH4,CH7,CH10,CH13

000-255

Red 1/2/3/4/5

CH2,CH5,CH8,CH11,CH14

000-255

Green 1/2/3/4/5

CH3,CH6,CH9,CH12,CH15

000-255

Blue 1/2/3/4/5

CH16

000-255

Color

CH17

000-255

Dimmer

CH18

000-255

Strobe

Summary of Contents for IntenZ CB-150

Page 1: ...IntenZ CB 150 RGB COB LED Matrix bar User manual...

Page 2: ...cover or remove the ground contact Never leave cables lying around Do not open the device and do not modify any hard or software of this unit Do not insert this object into air vents Do not connect th...

Page 3: ...f with the functions of the device before use Do not allow operation of the device by unskilled or unqualified people Use of the device in other ways than described in this user manual may cause damag...

Page 4: ...ct the unit to a power supply If the cable appears broken or has visible damage do not use it If the unit is not going to be used for a longer period of time disconnect it from the power supply and st...

Page 5: ...Bracket tightening knob 4 Rigging hardware 5 Menu display with buttons 6 On board microphone 7 Safety eye 8 DMX input 9 DMX output 10 Ventilation slot 11 Fuse 12 Twist lock Power input 13 Twist lock...

Page 6: ...ically A cool down time is applied until the temperature decreases back to 60 degrees Celsius When the temperature of the fixture does not decrease after several shut down actions check the following...

Page 7: ...array of several IntenZ CB 150 fixtures in vertical mode use the included hardware The small couplers are needed for a vertical array An unlimited amount of fixtures can be attached only if there is...

Page 8: ...turn the fixture in 3CH mode and set the starting address to value 003 the fixture will respond to channels 3 4 and 5 CHND The channel mode of the fixture makes it possible to use the correct channel...

Page 9: ...A short description for each mode can be found below Auto Automatic lightshow with a pre programmed internal show on a pre defined speed Sound Automatic lightshow with a pre programmed internal show o...

Page 10: ...st head Color CH2 000 255 The 2nd head Color CH3 000 255 The 3rd head Color CH4 000 255 The 4th head Color CH5 000 255 The 5th head Color CH6 000 255 Dimmer CH7 000 255 Strobe 15CH Mode CH1 CH4 CH7 CH...

Page 11: ...table colour temperature S L S Signal Loss Setting Blackout or sound controlled mode when no DMX signal is detected DMX operation 1 3 5 7 15 or 18 channels I T M Intelligent Temperature Monitoring red...

Reviews: