Setting up the unit

 

 
To activate the unit, connect the included power supply with the unit and a suitable 230V, 50 Hz power 
outlet. The unit will activate directly after it is plugged in to a wall outlet or other power source. 
 
Give the scanner time to calibrate the stepping motors, which are used to determine the position of the 
mirror. You may hear and see some shaking, which is normal. The stepping motors use an end point 
to determine the beginning and end of their movement. 

The displays shows a scrolling “RST” status. 

After calibration, the movinghead will start the previously used mode, but by default it is set to DMX 
mode. 
 
The status of the scanner is shown on the display. Certain values determine 
the current status and will change when you push buttons on the control panel. 
The buttons each have their own function, for easy navigation in the control 
panel.  
 
Press the ‘MENU’ button to switch modes, so you can easily select the built-in 
master/slave, music controlled or DMX mode.  
 
 

Display codes: 
 
DMX-Mode: 

A001:  

This value represents the DMX channel where the scanner is currently set to. 001 stands for channel 
1, but can be changed with the UP and DOWN buttons to a value from 001 to 255.  
When receiving DMX data, a small red dot on the display will blink continuously, regardless of what 
function is being used.  
 

Music controlled mode: 

When no DMX-signal is detected in DMX-mode, or when you select the master-mode, the unit will turn 
itself into music controlled mode. Use the microphone sensitivity potentiometer to adjust the sensitivity 
of the internal microphone for optimal light to sound functionality. When no music is detected, the 
scanner will play a slow automatic program until a beat or loud sound is detected.  
 

Master/Slave mode: 

S-1- / D  1: 

The D-value stands for the master-unit, which will use the internal microphone to perform music-
controlled. This fixture will send out a signal for slave fixtures, which you may connect using standard 
XLR male to XLR female cables (not included).  
The slave units show S-1- on the display, but a value of 0-4 can be chosen, using the UP and DOWN 
buttons. These values represent certain setting, for example pan/tilt invert, so your fixtures work 
synchronized while the mirror movements are inverted.  
 

Pan and tilt mode: 

P  0 / T  0

 

The pan and tilt values of every fixture can be reversed. This makes synchronized, but movement-
mirrored lightshows possible. The pan and tilt of every fixture can be mirrored individually.  
 
P  0 represents the Pan mode. The default is set to 0, which means a normal working mode. By using 
the UP and DOWN buttons you are able to select 0 or 1, where 1 is the inverted mode. 
 
T  0 represents the Tilt mode. The same settings apply here as described above. 
 

Summary of Contents for ALO 030

Page 1: ...1 30 Watt LED scanner User manual...

Page 2: ...proper bolts is also possible Make sure there are no flammable objects in the direct environment of the device Do not block the beam exit and fan Keep a minimum distance of 0 25 meter from any walls...

Page 3: ...sconnect it from the power supply and store it in a dust free environment Always check the unit for possible damage before use If you suspect that something is wrong with the unit do not connect it to...

Page 4: ...integrated fuse holder 7 Control panel display with MENU UP and DOWN buttons 8 Sound sensitivity potentiometer 9 Safety eye for optional safety cable 10 Built in microphone for sound active mode 11 DM...

Page 5: ...ink continuously regardless of what function is being used Music controlled mode When no DMX signal is detected in DMX mode or when you select the master mode the unit will turn itself into music cont...

Page 6: ...the correct address on the digital display you are able to choose a value between 001 and 255 When a DMX signal is received a blinking red dot on the display is active This unit has the following DMX...

Page 7: ...ndom strobe 248 255 Shutter open Channel 6 Dimmer 0 255 variable Channel 7 Movement macros Start value End value Function 0 7 No function 8 25 Movement macro 1 26 43 Movement macro 2 44 61 Movement ma...

Page 8: ...are protected against severe shocks exterior damage and failing electronics Make sure the moving parts of the scanner pan and tilt motors are secured during transport Shocks and fierce movement of mi...

Page 9: ...cleaner Do not touch the mirror and lens with your fingers as this may cause fingerprints which are harder to remove Checkup To prevent dangerous situations make sure your fixture is in optimal condi...

Page 10: ...adjustable Maximum flash rate 18 Hz Maximum ambient temperature 45 degrees Celsius Maximum distance from flammable surfaces 0 5m Power consumption 50W max Fuse 2A 250V 20mm glass fast blow Power supp...