83
82
G
TECHNISCHE SPEZIFIKATIONEN
Model
YGPH26-1080
Cooling Capacity (Btu/h)/ W
Heating Capacity
9.000 BTU/h / 2600W
8.500BTU/2500W
Dehumidifying Capacity (l/h)
1.1 l/h
Cooling Input Power/Current
Heating Input Power/Current
950 W/4,3A
900W/4.1A
Air Flow Volume (m³/h)
350 m³/h
Rated Voltage /Frequency (V/Hz)
220-240 V~/50 Hz
Sound Pressure Level (dB (A))
LPA
≤
54dB (A)
LWA
≤
65 dB (A)
Rated Energy Efficiency Ratio (EER rated)
2,6
Global Warming Potential (kg CO2)
2100
EER Class
A
Net Weight (Kg)
24 kg
Dimensions W X D X H
416 x 300 x 671 mm
Refrigerant
R410A
AApplying Space (m²)
18 m²
Miniature Fuse
3,15 A / 250 V ø5 x L 20 mm
TROUBLESHOOTING
The following cases may not always be a malfunction, please check
suggestions below before asking for service.
Trouble
Analysis
Does not run
1. If the protector trip or is blown.
2. Please wait for 3 minutes and start again, protector device may
be preventing unit from working.
3. If batteries in the remote controller are exhausted.
4. If the plug is not properly plugged in
Runs for a short while
only
1. If the set temperature is close to room temperature, you can
lower the set temperature.
2 . Air outlet is blocked by obstacle. Take the obstacle away.
Runs but not cooling
1. If the door or window is open
2. If there is another appliance heat-working .like heater or lamp,
etc.
3. The air filter is dirty, please clean it.
4. Air outlet or intake is blocked.
5. Set temperature is too high.
Water leak during
moving
1. Drain the condensate before moving
2. To avoid water leakage,
Does not run
and water full
indicator"E4"
1. Pull out the rubber pug to drain water.
2. If it is often in this state, please contact qualified service technical.