28
Note: This control is not active when the amplification mode
switch is in ''Fullrange'' position!
⑨
SUBSOniC FilTEr
Crossover frequency control allowing the setting of the sub-
sonic cut-in frequency between 15 and 50 Hz.
••
AmPliFiCATiOn mODE SWiTCH
Depending on the selected switch setting the amplifier ope-
rates in Highpass, Lowpass or Fullrange mode.
••
HPF FilTEr
Crossover filter frequency control allowing the setting of the
High-pass cut-in frequency between 50 and 250 Hz.
Note: This control is not active when the amplification mode
switch is in ''Fullrange'' position!
••
inPUT gAin
Input gain/sensitivity control allowing the matching of the
amplifier input section to the head-unit (pre-out)
output voltage.
f
inPUT CH5
Low-level RCA input for connection to head-unit pre-out.
g
inPUT CH1-CH4
Low-level RCA input for connection to head-unit pre-out.
nOTE:
⑧ •• ••
Upper row for CH1 and CH2. Lower row for CH3 and CH4.
Left side for CH5.
q
grOUnD/gnD
Power connection terminal to chassis ground or negative
terminal of car battery.
w
rEmOTE/rEm
Remote switching contact for the automatic (remote) toggle-
on/off of the power amplifier from the head-unit's
remote lead.
e
+12 V
Power connection terminal to positive terminal of car battery.
r
FUSE
Fuses for protection of the amplifier-internal electronics
against overload or faulty operation / wrong manipulation.
t
+
CH1
– through
– CH4
+
Speaker output terminals for one stereo speaker pair or one
single speaker connected in bridged mode (e.g. subwoofer).
in bridged mode the minimum speaker impedance is 4 ohms!
y
POWEr lED/PrOTECT lED
Lit green when power is on.
Lit red when amplifier is in pro-
tect mode due to shorted speakers, overtemp. etc.
u
rEmOTE POrT
Input for RJ11 jack, for the external bass level remote control.
⑧
lPF FilTEr
Crossover filter frequency control allowing the setting of the
Lowpass cut-off frequency between 50 and 250 Hz.
B4
COnnECTiOnS AnD COnTrOlS AXTOn A480-250
Summary of Contents for A1390
Page 5: ...5 Anschlüsse Bedienungselemente A1390 q w e r t y u i o ...
Page 7: ...7 Anschlüsse Bedienungselemente A2090 A2190 q w e r t y u i o q w e r t y i o ...
Page 9: ...9 Anschlüsse Bedienungselemente A490 q w e r t y u i o ...
Page 11: ...11 Anschlüsse Bedienungselemente A480 250 q w e r t y u i o f g ...
Page 20: ...20 ...
Page 23: ...23 Connections Controls A1390 q w e r t y u i o ...
Page 25: ...25 Connections Controls A2090 2190 q w e r t y u i o q w e r t y i o ...
Page 27: ...27 Connections Controls AXTON A490 q w e r t y u i o ...
Page 29: ...29 Connections Controls A480 250 q w e r t y u i o f g ...
Page 38: ...38 ...
Page 41: ...41 Connections et réglages AXTON A1390 q w e r t y u i o ...
Page 43: ...43 Connections et réglages A2090 2190 43 q w e r t y u i o q w e r t y i o ...
Page 45: ...45 Connections et réglages AXTON A490 45 q w e r t y u i o ...
Page 47: ...47 Connections et réglages AXTON A480 250 q w e r t y u i o f g ...
Page 55: ...55 ...
Page 58: ......