AXT ELECTRONIC VSE Insruction Manual Download Page 4

Status Display

To check the settings, activate the display by briefly touching one of the three control pa-

nels                      with the red magnet. The display shows the current status of the Doorkee-

per VSE. Following this, the settings for the entire week will be briefly displayed in order to 

check the values. The display deactivates automatically.

MENU OPERATION

Programming via the operating elements

Menu: Activate main menu (press for 3s) / Confirm Input (save)

Back: Decrease by one value in the step / Back to menu

Up: Move forward one value in the step / Scroll up menu

Down: Move backward one value in the step / Scroll down menu

Main Menu and Settings

To activate the main menu, hold the red magnet for 3 seconds against the “Menu” control 

panel. By scrolling with „Up“ or „Down“ you can select one of the 9 menu options. Hold 

the red magnet again against „Menu“ to navigate to the selected menu item and change 

the settings. With „Up“ and „Down“ you can change the selected values, with „Menu“ you 

confirm and save your settings, afterward, you will then be automatically taken to the 

next value. Once all sub-menus have been scrolled through and saved, you automatically 

return to the main menu.  To exit the menu, select menu item 9 and confirm. After approx. 

1 minute, the menu will be automatically exited if no entries are made. The menu/display 

is also deactivated if, for example, the engine starts up during menu operation because the 

device has detected darkness.

„LIGHT THRESHOLD“ Light Sensitivity

For the combined control „LUX AND TIME“ and the twilight control „ONLY LUX“, the light 

sensitivity of the light sensor can be adjusted from 1 - 10 lux. 1 Lux is for closing later in 

the evening and opening earlier in the morning. (Note: with this minimum setting for the 

opening mode, there is a risk that the door will also be opened at night if there is strong 

moonlight or scattered light due to snow or outdoor lighting) – 10 Lux is for closing earlier 

in the evening and opening later in the morning. (Note: With this maximum setting for the 

closing mode, the door may also be closed during a heavy thunderstorm during the day.) 

The value for „Open“ should be at least one value higher than the value for „Close“.

The Term LUX:

In the working modes, „LUX“ means that the light sensor is also responded to. If this information 
is missing, the light sensor value is not observed. In relation to the sensitivity setting, Lux stands 
for light intensity.

„LIGHT DELAY“ Twilight Delay

If you want to close the door well after dark, use the light delay which can be set in the closing 

mode. Here, the delays are adjustable from 1 to 90 minutes. An active twilight delay can be 

interrupted or terminated by a closing time or the manual control, thus closing the device 

prematurely.

1. Time of day

2. Opening mode

3. Closing mode

4. Language

5. Date

6. Daylight saving

7. Cursor-Type

8. Reset

9. EXIT

LUX AND TIME

LUX AND TIME

Light threshold

Light threshold

Light delay

Light threshold

Light threshold

Light delay

Mo - Su

Mo - Su

Sa - Su

Sa - Su

Sunday

Sunday

ONLY TIME

ONLY TIME

ONLY LUX

ONLY LUX

MANUELL

MANUELL

german
english
french

Day Symbol

manual controlled

Night Symbol

Time

Weekday

Open time

Twilight control

Close time

Door closed

Date

Information Weekdays: 

Weekend time setting always overwrites the total week time.
Sunday time settings always overwrites the weekend and total week time. When you 
save new settings for the entire week, any deviating weekend and Sunday times will be 
overwritten. Therefore, first set the time for the whole week, reenter the menu and then 
change the times for weekends or Sundays if desired.

Overview menu navigation

no twilight controled

Day Symbol

Time

Weekday

Door opened

Date

Summary of Contents for VSE

Page 1: ...he Electronic Doorkeeper VSE Please note the general information on the back of this sheet and the safety instructions in the manual AXT electronic GmbH Co KG Wartburgstrasse 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic de ...

Page 2: ...e evening the Doorkeeper VSE closes automatically when it gets dark or at the latest 10 o clock p m General Information A long battery life is guaranteed if you only use AA Mignon alkaline batteries If the batteries in your new device last only a few days or weeks there is most likely a mounting error e g door blockage Via manual operation with the red magnet check to see if the door can be comple...

Page 3: ...f the polari ty is reversed the LED flashes red regularly after closing not green Manual Controlling SA Function Opening and closing of the door by holding the red magnet against the SA marking Twilight Sensor When using the out door light sensor ASb please unscrew the internal sensor or darken it comple tely with a black cap up to the screw terminal LED Indicators Device in Closed Mode 1x green L...

Page 4: ...g for the opening mode there is a risk that the door will also be opened at night if there is strong moonlight or scattered light due to snow or outdoor lighting 10 Lux is for closing earlier in the evening and opening later in the morning Note With this maximum setting for the closing mode the door may also be closed during a heavy thunderstorm during the day The value for Open should be at least...

Page 5: ...After approx 1h no further attempt is made to open Actuate the SA to get the device out of the error state It will close and you can remove the blockade Cord very tight in opened condition Limit stop does not work If the white limit switch is pulled extremely far towards the motor a component of the limit switch is defective Please send the device for repair Slider blocks during opening The limit ...

Page 6: ...sion for repair 1 You cannot resolve the error using the table 2 Contact us if you are not sure what to send If possible send pictures of the devices in advance by e mail cover open assembly with door 3 We usually need the devices accessories such as external sensors or the timer together for repair 4 We do not need the aluminum door with us 5 Remove the devices from the installation site Remove t...

Page 7: ...tronic GmbH Co KG Wartburgstraße 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic eu Electronic Doorkeeper VSE First steps and basic settings in the menu navigation ...

Page 8: ...ositioned on YEAR Year Month Day Use up or down to set current year Confirm with ok 8 Cursor is positioned on MONTH Year Month Day Use up or down to set current month Confirm with ok 9 Cursor is positioned on DAY Year Month Day Use up or down to set current day Confirm with ok The use ESC Back leads to canceling these three settings Default values then are applied These can have to be corrected la...

Page 9: ...em returns to the Opening Mode menu item 6 Press down up to select a new menu item for setting or select and confirm the last menu item EXIT or wait 1 minute and do not operate anything to have the menu guidance end automatically d For closing set LUX ONLY mode close only at dusk no Time 1 activate the Menu hold Magnet for 3sec at OK Menu 2 Mark the menu item Closing Mode with 2x down Press Ok to ...

Page 10: ...ith OK Use up down to select the LUX AND TIME mode if it is not set but is to be used Confirm the LUX AND TIME mode with OK if it has not already been set 5 Change the opening time selection from Monday Sunday MO SU with 1x down to Saturday Sunday SA SU With 1x OK place the cursor on the HOUR hh mm of the opening time 6 Use up and down to set the desired new opening time If no minutes are to be se...

Reviews: