OPTIONAL ACCESSORIES

Electronic Doorkeeper VSE

Power Supply
The power supply unit is connected to the contacts 1 at the bottom (blue cable) and 2 at 

the top (red cable). After plugging in the power supply, the Doorkeeper VSE starts (LED 

flashes several times, the last green, display shows status information, and then welcome... 

) and is now ready for operation (LED and display off). If the cord was unwound, it is now 

fully retracted. 

Outdoor-light Sensor ASb 
The cables of the outdoor-light sensor are marked blue. Connect the cables of the out-

door-light sensor to the contacts 6 (white cable) at the bottom, and 5 (brown cable) at the 

top. When using the ASb, please unscrew the internal twilight sensor (see sketch above) 

or darken completely with a black cap.

External Manual Control SA 
The cables of the external manual control are marked red.

Connect the cables of the external SA to the contacts 8 (white cable) at the bottom and 

7 (brown cable) at the top.

 Instead of the external manual control with magnet, a separate 

button (non-locking, not a switch!) can also be connected here to manually control the Door-
keeper VSE.

External LED 
The cables of the external LED are marked green. Connect the cables of the external LED 

to the contacts 10 (white cable) at the bottom and 9 (brown cable) at the top.

 (If the polari-

ty is reversed, the LED flashes red regularly after closing, not green).

Manual Controlling

„SA-Function“

Opening and closing of 

the door by holding the 

red magnet against the 

SA marking.

Twilight Sensor

When using the out-

door-light sensor ASb, 

please unscrew the internal 

sensor or darken it comple-

tely with a black cap (up to 

the screw terminal!).

LED-Indicators

Device in Closed Mode (1x green)

Light flashes when the Doorkeeper VSE has received the signal to close the door and the 

internal limit switches confirm that no further weight is pulling on the device. Therefore, 

the door should now be closed. 

Please check the door regularly for smooth running to pre-

vent it from getting stuck when closing.

Batteries Expired (2x red)

You should replace the batteries to ensure safe operation.

 For optimum battery life, use only 

alkaline batteries.

Error Limit Switch (3x red)

Limit switch error for open mode. The cord is possibly wound incorrectly or the maximum 

stroke of 70cm is not sufficient. 

This error is also indicated when the limit switch for the open 

mode is raised during the closing movement!

Error Overload (1x red)

Door is blocked when opening. 

Check for the smooth opening and closing of the door with 

the manual control.

Information:  

The LED signal for the error or 

operating mode is only displayed for 

approx. 2 hours after activation in 

short intervals. 

The LED therefore does 

not flash all night long!

Po

wer S

upply

Out

door ligh

t sensor

Ex

ternal man. c

on

trol

Ex

ternal LED

Summary of Contents for VSE

Page 1: ...he Electronic Doorkeeper VSE Please note the general information on the back of this sheet and the safety instructions in the manual AXT electronic GmbH Co KG Wartburgstrasse 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic de ...

Page 2: ...e evening the Doorkeeper VSE closes automatically when it gets dark or at the latest 10 o clock p m General Information A long battery life is guaranteed if you only use AA Mignon alkaline batteries If the batteries in your new device last only a few days or weeks there is most likely a mounting error e g door blockage Via manual operation with the red magnet check to see if the door can be comple...

Page 3: ...f the polari ty is reversed the LED flashes red regularly after closing not green Manual Controlling SA Function Opening and closing of the door by holding the red magnet against the SA marking Twilight Sensor When using the out door light sensor ASb please unscrew the internal sensor or darken it comple tely with a black cap up to the screw terminal LED Indicators Device in Closed Mode 1x green L...

Page 4: ...g for the opening mode there is a risk that the door will also be opened at night if there is strong moonlight or scattered light due to snow or outdoor lighting 10 Lux is for closing earlier in the evening and opening later in the morning Note With this maximum setting for the closing mode the door may also be closed during a heavy thunderstorm during the day The value for Open should be at least...

Page 5: ...After approx 1h no further attempt is made to open Actuate the SA to get the device out of the error state It will close and you can remove the blockade Cord very tight in opened condition Limit stop does not work If the white limit switch is pulled extremely far towards the motor a component of the limit switch is defective Please send the device for repair Slider blocks during opening The limit ...

Page 6: ...sion for repair 1 You cannot resolve the error using the table 2 Contact us if you are not sure what to send If possible send pictures of the devices in advance by e mail cover open assembly with door 3 We usually need the devices accessories such as external sensors or the timer together for repair 4 We do not need the aluminum door with us 5 Remove the devices from the installation site Remove t...

Page 7: ...tronic GmbH Co KG Wartburgstraße 10 99817 Eisenach GERMANY Phone 0049 3691 721070 service axt electronic de www axt electronic eu Electronic Doorkeeper VSE First steps and basic settings in the menu navigation ...

Page 8: ...ositioned on YEAR Year Month Day Use up or down to set current year Confirm with ok 8 Cursor is positioned on MONTH Year Month Day Use up or down to set current month Confirm with ok 9 Cursor is positioned on DAY Year Month Day Use up or down to set current day Confirm with ok The use ESC Back leads to canceling these three settings Default values then are applied These can have to be corrected la...

Page 9: ...em returns to the Opening Mode menu item 6 Press down up to select a new menu item for setting or select and confirm the last menu item EXIT or wait 1 minute and do not operate anything to have the menu guidance end automatically d For closing set LUX ONLY mode close only at dusk no Time 1 activate the Menu hold Magnet for 3sec at OK Menu 2 Mark the menu item Closing Mode with 2x down Press Ok to ...

Page 10: ...ith OK Use up down to select the LUX AND TIME mode if it is not set but is to be used Confirm the LUX AND TIME mode with OK if it has not already been set 5 Change the opening time selection from Monday Sunday MO SU with 1x down to Saturday Sunday SA SU With 1x OK place the cursor on the HOUR hh mm of the opening time 6 Use up and down to set the desired new opening time If no minutes are to be se...

Reviews: