background image

4

Install the pop-up drain

Remove the plunger assembly.

Unscrew the drain outlet flange from the 

tee.

Unscrew the tailpiece from the tee.  Wrap 

the threads with two layers of Teflon tape 

and replace. 

Install the white, flexible sealing gasket to 

the flange.  Place it in the sink outlet. 

From under the sink, install the black mack 

gasket, white friction ring  and retainer 

nut  to the flange. Do not tighten the nut 

against the bottom of the sink at this time.

Thread the tee and tailpiece to the flange.  

The pivot must face the faucet.  If neces-

sary, turn the drain assembly.

Tighten the retainer nut.  

Place the plunger assembly in the drain. 

Install the horizontal rod so that the end 

goes through the loop in the bottom of the 

height adjuster.

Install and hand tighten the pivot ball nut.

Attach the swivel connector to the end of 

the horizontal rod.  

Attach the swivel connector to the end of 

the vertical rod.   Position as desired and 

tighten with a small, flathead screwdriver.

plunger

flange

sealing gasket

mack gasket

friction ring

retainer nut

horizontal rod

height adjuster

pivot ball nut

swivel connector

vertical rod

tee

tailpiece

Summary of Contents for Steel 35002801

Page 1: ...Axor Steel 35002801 Installation Instructions Warranty Axor Steel 35202801 ...

Page 2: ...e local codes when setting the temperature on the water heater Installation Considerations For best results Hansgrohe recommends that this faucet be installed by a licensed pro fessional plumber The pressure of the hot and cold supplies should be balanced The supply lines included with this faucet are 3 8 3 8 compression fittings not included are required for installation Axor Steel Lavatory Fauce...

Page 3: ...n top of the mounting surface From beneath install the fiber washer metal washer and mounting nut Tighten them against the bottom of the mounting surface Tighten the tensioning screws Place a 3 8 compression fitting over each hose shank Insert in the stop Tighten wrench tight ...

Page 4: ... tee and tailpiece to the flange The pivot must face the faucet If neces sary turn the drain assembly Tighten the retainer nut Place the plunger assembly in the drain Install the horizontal rod so that the end goes through the loop in the bottom of the height adjuster Install and hand tighten the pivot ball nut Attach the swivel connector to the end of the horizontal rod Attach the swivel connecto...

Page 5: ...ndle If necessary turn the stem so that it is centered Remove the screw Remove the green high temperature limit stop Reinstall the limit stop so that the pin is in the desired slot on the limit stop The degree markings shown on the diagram assume an incoming hot water tempera ture of 140oF and a incoming cold water temperature of 50oF Thread the handle screw back into the stem giving it four compl...

Page 6: ...ent Parts 1 2 3 4 5 7 1 handle 35093800 1 1 screw cover 96681000 2 nut cover 96682800 3 nut 96690000 4 M3 cartridge 92730000 5 seal 95008000 6 mounting kit 13961000 7 pull rod 96657800 8 aerator 96683800 1 1 8 6 ...

Page 7: ...itchen faucets and showers consist of very different materials to comply with the needs of the market with regard to design and functionality To avoid damage and returns it is necessary to consider certain criteria when cleaning Cleaning Materials for Faucets and Showers Acids are a necessary ingredient of cleaning materials for removing lime however please pay attention to the follow ing points w...

Page 8: ...livery of the product or the defective part postage prepaid and carefully packed and insured to Hansgrohe Inc 1492 Bluegrass Lakes Parkway Alpharetta Georgia 30004 Attention Technical Service if required by Hansgrohe When warranty service is completed any repaired or replacement product or part will be returned to you postage prepaid EXCLUSIONS AND LIMITATIONS REPAIR OR REPLACEMENT OR IN LIMITED C...

Reviews: