Connecting cable between light/transform
Cable length:
7 m
Wire cross section:
approx. 0,25 mm²
– Wire color:
black (GND)
+ Wire color:
red (12 V DC)
Protection type of plug to the light:
IP 68
Connection on the transformer:
Clamp connection
Empty conduit for cable:
EN 20
If the connecting cable is shortened, it must be fitted with
0.25 mm² wire end plugs and a contact length of 8 mm.
Cleaning / Repair
Cleaning recommendations, see enclosed brochure.
Fault
Cause
Remedy
Light does not light up
- No mains power
- Check input/output voltage of the
transformers
- Transformer defective
- Replace transformer
- Illuminant defective
- Replace illuminant
Technical Data
Light
Nominal voltage:
12 V DC / 50 Hz SELV
Power:
3 W
Protection class:
IP X5
Serial number:
40871000 (see typeplate)
Dimensions:
see page 60
weight:
739 g
transformer
Input (IN): 100 – 240 V / 50 – 60 Hz / 70 – 170 mA
Output (OUT):
12 V DC / 500 mA
Protection class:
IP 20
Serial number:
19769610 (see typeplate)
Dimensions:
see page 60
weight:
81 g
The transformer must not be installed in protection zones
0, 1 or 2.
The transformer must be installed inside the wall in a
socket. This socket inside the wall is connected to the
light via an empty conduit EN 20.
The specifications are identical to the data on the type
plate for the light and the transformer.
installation.
All components must remain accessible.
The ambient temperature must not exceed 40 ºC.
Standards and guidelines
If installed and used as intended, the light and the
respective transformer fulfill the standards EN 60598-
2-2 / EN 60335-2-105 as well as the low voltage and
EMC guidelines.
Illuminant change
Any work may only be carried out in a de-energized
state. Here, the voltage supply must be safely separated
via the main switch or mains plugs.
The operator can perform the illuminant change.
Illuminant (3,6 W / 0,3 A / 3200 K)
Order number: 95465000
Illuminant change see page 63
All spare parts must be purchased at the dealer’s.
Summary of Contents for Starck 40871000
Page 60: ...60 95587000 97663000 96338000 95465000 95585000 3 6 W 0 3 A 3200 K 95586000 2 m m...
Page 61: ...61 3 1 4 1 2 2 5 Silikon IN 100 240 V 70 170 mA OUT 12 V DC 500 mA min 100 mm max 7 m...
Page 62: ...62 3 8 11 1 2 Silikon 9 10 5 Nm 7 0 14 14 28 6 28 42 1 2...
Page 63: ...63 2 mm 1 Nm 12 2 mm 1 2 3 3 4 1 2...
Page 65: ...65...
Page 66: ......
Page 67: ......