Electrician
The installation and test work must be performed by an
authorized electrician under consideration of DIN VDE
0100 part 701 / IEC 60364-7-701.
Electrical connection
Voltage supply: 100 – 240 V / N /PE / 50 – 60 Hz
Residual current protection system
The circuit must be protected via a ground fault protector
(RCD / FI) with a measured differential current of ≤ 30
mA.
The proper function of this fusing/protection must be
checked at regular intervals.
Any work may only be carried out in a de-energized
state. Here, the voltage supply must be safely separated
via the main switch or mains plugs.
Consistency of installation surface
Please also make sure that the installation surface
is even. If there are deep ridges or offset tiles, it is
necessary to even out this unevenness using silicone.
First, the basic set order no. 40876180 must be
installed.
Pull the connecting line to light/transformer into the
empty conduit by means of a cable retractor (EN 20).
Only standardized materials may be used for the
Assembly
(see page 61)
Beware of dangerous electrical
current
Do not use silicone that contains acedic
acid.
Symbol description
English
Safety Notes
Electrical installation
Intended Use
Light
The light type 40871000 is only suited for use in interior
rooms, baths and showers in zones type 1 and 2 as
well as outside as per DIN VDE 0100 part 701 / IEC
60364-7-701 and must only be powered with SELV 12
V DC.
transformer
The voltage supply from the 12 V DC SELV must only be
fed via the included transformer type 19769610. The
transformer must be installed outside the zones 0, 1 and
2 in a socket in the wall - safe from outside contact.
The mains voltage of 100 - 240 V AC 50 - 60 Hz must
be supplied via a shutoff device (switch) as well as
a ground fault protector (RCD / FI) with a measured
differential current of ≤ 30 mA.
The transformer type 19769610 is only suited for the
Read the installation instructions
Spare parts
(see page 60)
Dimensions
(see page 60)
Product description
The Axor Starck ShowerCollection light type 40871000
is a 12 V 3 W IP X5 built-in LED and is used to illuminate
baths and showers.
voltage supply of the light type 40871000.
A different or excessive use is considered non-intended.
The user/operator bears the sole risk. The intended use
includes the adherence to the operating instructions
and the observance of the inspection and maintenance
guidelines.
The manufacturer/seller of this light does not assume
any responsibility for injuries or damage that may be
caused by improper installation or non-intended use.
Important notice
Repair
(see page 63)
Installation Instructions
Summary of Contents for Starck 40871000
Page 60: ...60 95587000 97663000 96338000 95465000 95585000 3 6 W 0 3 A 3200 K 95586000 2 m m...
Page 61: ...61 3 1 4 1 2 2 5 Silikon IN 100 240 V 70 170 mA OUT 12 V DC 500 mA min 100 mm max 7 m...
Page 62: ...62 3 8 11 1 2 Silikon 9 10 5 Nm 7 0 14 14 28 6 28 42 1 2...
Page 63: ...63 2 mm 1 Nm 12 2 mm 1 2 3 3 4 1 2...
Page 65: ...65...
Page 66: ......
Page 67: ......