0 4
A S S E M B L Y (see page 31)
F A U L T
C A U S E
R E M E D Y
⁄ Mixer stiff
⁄ Cartridge defective, calcified
⁄ Exchange cartridge
⁄ Mixer dripping
⁄ Cartridge defective
⁄ Exchange cartridge
⁄ Water escaping at the threaded base
⁄ connection hoses not completely screwed into basic body
⁄ Tighten connection hoses by hand
⁄ O-ring at the connection hose defective.
⁄ Exchange O-ring
⁄ Hot water temperature too low
⁄ Hot water limiter incorrectly set
⁄ Set hot water limiter
S P A R E P A R T S (see page 36)
S P E C I A L A C C E S S O R I E S (order as an extra)
service tool #95910000 (see page 36)
F L O W D I A G R A M (see page 35)
Normal spray
Regular
D I M E N S I O N S (see page 35)
M A I N T E N A N C E (see page 34)
The check valves must be checked regularly according to DIN EN 1717 in
accordance with national or regional regulations (at least once a year).
C L E A N I N G (see page 34 and enclosed brochure)
If the waterflow drops, clean the filter located between hose and handspray.
O P E R A T I O N (see page 34)
⁄ Hansgrohe recommends not to use as drinking water the first half liter of
water drawn in the morning or after a prolonged period of non-use.
⁄ Do not rotate the spout further than 360º or damage to the hose will
result.
A D J U S T M E N T (see page 33)
To adjust the hot water limiter. Using a hot water limiter in combination with a
continuous flow water heater is not recommended.
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
S A F E T Y N O T E S
Gloves should be worn during installation to prevent crushing and cutting injuries.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport damages. After it has been
installed, no transport or surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and tested as per the applicable
standards.
⁄ The plumbing codes applicable in the respective countries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 – 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection:
max. 70°C ⁄ 4 min
The product is exclusively designed for drinking water!
EN
T E S T C E R T I F I C A T E (see page 36
Summary of Contents for Citterio 39835000
Page 36: ...3 2 6b 24 x 15 110 1 0 CLICK 7 8 9 10 11 12 110 55 25 55 85 85 25 ...
Page 41: ...3 7 ...
Page 42: ...3 8 ...
Page 43: ...3 9 ...