S A F E T Y N O T E S
Gloves should be worn during installation to prevent
crushing and cutting injuries.
Children as well as adults with physical, mental and⁄or
sensoric impairments must not use this product without
proper supervision. Persons under the influence of alco-
hol or drugs are prohibited from using this product.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal pressures.
I N S T A L L A T I O N I N S T R U C T I O N S
⁄ Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
⁄ The pipes and the fixture must be installed, flushed and
tested as per the applicable standards.
⁄ The plumbing codes applicable in the respective coun-
tries must be observed.
T E C H N I C A L D A T A
Operating pressure:
max. 1 MPa
Recommended operating pressure:
0,1 - 0,5 MPa
Test pressure:
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
max. 70°C
Recommended hot water temp.:
65°C
Thermal disinfection
max. 70°C ⁄ 4 min
Safety against backflow
The product is exclusively designed for drinking water!
This mixer cannot be used in conjunction with hydrauli-
cally, electronically or thermally controlled instantaneous
heaters.
F L O W D I A G R A M
(see page 68)
Rate of flow by 0,3 MPa:
M A I N T E N A N C E (see page 65)
⁄ The mixer is equipped with check valves.
The check valves must be checked regularly
according to DIN EN 1717 in accordance
with national or regional regulations (at least
once a year).
⁄ To guarantee the smooth running of the ther-
mostat, it is necessary from time to time to turn
the thermostat from total hot to total cold.
A D J U S T M E N T (see page 63)
After the installation, the output temperature of
the thermostat must be checked. A correction is
necessary if the temperature measured at the
output differs from the temperature set on the
thermostat.
S A F E T Y F U N C T I O N (see page 63)
The desired maximum temperature for example
max. 42º C can be pre-set thanks to the safety
function.
D I M E N S I O N S (see page 67)
O P E R A T I O N (see page 68)
C L E A N I N G
see enclosed brochure.
Do not use silicone containing acetic acid!
S Y M B O L D E S C R I P T I O N
EN
Summary of Contents for Bouroullec
Page 25: ...2 5 ZH 60 A 42 C 65 C 180 180 69 XXX 000 090 820 930 Polished Brass 80...
Page 27: ...2 7 RU 60 A 42 65 180 69 XXX 000 090 820 brushed nickel 930 Polished Brass 80...
Page 43: ...4 3 EL 60 A 42 C 65 C 180 180 69 XXX 000 090 820 930 Polished Brass 80...
Page 55: ...5 5 BG 60 A 42 C 65 C 180 180 69 XXX 000 090 820 930 Polished Brass 80...
Page 58: ...5 8 AR 60 A 42 65 180 180 69 XXX 000 090 820 Polished Brass 930 80...
Page 59: ...5 9 1 0 5 0 1 1 6 PSI 147 10 1 70 C 65 C 4 70 C 68 0 3 65 DIN EN 1717 63 63 42 67 68 AR...
Page 60: ...6 0 2 3 1 X 1 2 mm SW 4 mm 5 Nm 2 5 6 2 4 X 11 3 2 3 1 1 2 01800180 1...
Page 64: ...6 4 2 3 2 1 1 SW 3 mm SW 3 mm z B 42 C for example 42 C 2 1 1 2 3 3 5 4 6 8a 8b 7 SW 2 mm 2 Nm...