background image

U

SER

M

ANUAL

 

 

CS 2000 BT Wireless Handheld Gun Type Scanner 

20 

Connecting to a Host 

The scanner provides several data transmit methods to communicate with the host. User 
may select the method according to their preferences. Read this section to learn the 
setups for connecting to different hosts. 
 

 

Start Of Configuration 

 

USB Online Mode 

The scanner connects directly to a USB host to recharge and transmit data. You may 
enable or disable the functions using the following settings. 
 
Disable USB communication 
 

 

USB online scan disable 

Disable USB communication. 

 
Enable USB communication 
 

 

USB online scan enable 

Wireless connection as the primary communication 
option to the host. USB connection is only used when 
wireless is disconnected. 

 
 
Set USB as the primary connection 
 

 

USB online scan, Ignore 

radio communication 

 

USB connection as the primary communication option 
to the host when it is available. Wireless mode is set 
as the secondary option. 

 
 
 
 

 

End Of Configuration 

Summary of Contents for CS2000

Page 1: ...CS 2000 Wireless Handheld Gun Type Scanner ...

Page 2: ......

Page 3: ...CS 2000 Wireless Handheld Gun Type Scanner i USER S MANUAL Revision History Changes to the original manual are listed below Version Date Description of Version 1 0 Dec 20 2011 Axon Initial release ...

Page 4: ...l chemical biological manual or otherwise except for brief passages which may be quoted for purposes of scholastic or literary review without express written consent and authorization We reserve the right to make changes in product design without reservation and without notification The material in this guide is for information only and is subject to change without notice All trademarks mentioned ...

Page 5: ...urer and authorized dealer or experienced radio television technician for additional suggestions The user may find the following booklet prepared by the Federal Communications Commission helpful How to Identify and Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 U S A Stock No 04000003454 0 Laser Safety This equipment gen...

Page 6: ...he eye hazard Optical instruments include binoculars magnifying glasses and microscopes but do not include normal eye glasses worn by the user CAUTION Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure For CE Countries This scanner is in conformity with CE standards Please note that an approved CE marked power su...

Page 7: ...canner 7 How to Scan 8 Radio Communication Host Type 9 Cradle Host Mode 9 SPP Mater SPP Slave Mode 9 HID Mode 9 Paging the Scanner 10 Scanner USB online to Host 10 USB Online Mode 10 Visible Indicators 10 Scanner 10 Cradle 11 Sound Indicators 12 ACK NAK Protocol or Frame Packing 12 Scanner to Remote Application 14 Programming Guide 16 Connecting to a Host 20 USB Online Mode 20 Cradle Host Mode 21 ...

Page 8: ......

Page 9: ...ransferred to the connected host in a 100 meter connection range in open space or 75 meter range in indoor environments the actual communication range may vary due to different indoor placement This feature eliminates hazardous cables and creates a safer work environment Either scanning in the handheld or hands free mode this scanner always offers a high accuracy and reliable scanning ability This...

Page 10: ...n Type Scanner 2 Product Overview Scanner LED Indicator Exit Window Buzzer Metal Charging Contacts Trigger Strap Hole Cable Connector Cradle Function Trigger LED indicator Charging Contacts Host Connector DC Power Connector Bluetooth Address Label ...

Page 11: ...ss scanner with battery Scanner cradle optional with cradle without cradle Li ion battery pack Communication cable for cradle optional Mini USB B to mini USB A cable 5V USB Power adapter CD ROM or handbook Containing manual and programming guide If any contents are damaged or missing please contact your dealer immediately ...

Page 12: ...to install the batteries Always use the rechargeable batteries provided by the manufacturer to avoid any non compatible danger or void the warranty 1 Unscrew the cap from the battery compartment at the bottom of the scanner and insert the battery 2 Make sure the red tag on the battery is tugged in and not blocking the cable connector and close the cap 3 Tighten the screw on the cap to secure the b...

Page 13: ...t the RJ 45 connector on the bottom of the cradle You will hear a clear and short click sound then connect the other end to the host 2 Connect the included USB cable of mini USB port in the bottom of the cradle and connect other end to USB power adaptor 3 Connect the USB power adaptor into AC outlet The LED indicator on the cradle should flash blue until it made connection with the scanner Communi...

Page 14: ...begins charging when the scanner LED indicator starts flashing green LED turns steady green when charging is complete Approx charging time 4 5 hours To charge the battery using the USB cable There are two method to charge scanner via USB cable Host USB Power Power adaptor 1 Connect the mini USB connector directly to the scanner 2 Connect the other end of the USB connector to the host to begin char...

Page 15: ... may not be full charged and should be fully charged for maximum charge capacity Recommended charging environment is temperature in 0 C 35 C 32 F 95 F Power on the Scanner 1 Ensure the battery is fully charged Please refer to the previous section to charge the battery 2 Press and hold the trigger for 1 second until a long beep sound is heard to turn on the scanner ...

Page 16: ...ng 1 Power on the scanner 2 Press the trigger and aim at the barcode as illustrated 3 When decoding is successful the scanner beeps and the LED indicates blue Presentation Scanning 1 Put the scanner into the cradle for presentation scanning 2 Move the barcode label approach the scanner scanning zone 3 When decoding is successful the scanner beeps and the LED indicates blue ...

Page 17: ... the same delivery box are paired in factory As soon as both are powered on they should find and connect to each other immediately However under special circumstance that the scanner and the cradle are not paired with the cradle please See Cradle Host Pairing for detail operation information SPP Mater SPP Slave Mode The scanner communicates with the host through wireless connection Please see Wire...

Page 18: ...nge Scanner USB online to Host The scanner provides other ways for you to connect to the host When the radio communication is not available the scanner can be connected to transmit data via USB Online mode Please see USB Online Mode for detail operation information USB Online Mode The scanner connects directly to a USB host to recharge and transmit data Visible Indicators Scanner There are 2 group...

Page 19: ...harging mode Steady Green Battery fully charged Steady Red Programming mode Red flashing slow with continuous beep sound Low battery warning Red flash twice with 2 beep sound Very low battery warning Cradle Cradle LED LED Status Indication Red steady and blue continuous flashing Cradle is radio disconnected and power from DC adaptor is lost Steady red and blue Cradle is radio connected But lost DC...

Page 20: ...r saved in the memory 1 high low high beeps Scan cradle pair barcode Four short medium beeps Data communication failed or out of range Intermission medium low beeps Low battery warning 1 short medium low beeps Scanner is power down 1 long high medium beeps Enter programming mode 1 long medium medium beeps Exit Programming mode ACK NAK Protocol or Frame Packing When scanner is in SPP Master Slave m...

Page 21: ...d Gun Type Scanner 13 a No ACK NAK protocol b ACK NAK only c Frame packing BT Scanner Remote BT device BT scanner Remote BT device data data NAK Resend ACK Get a good beep BT scanner Remote BT device Data format of Acknowledge Get a good beep ...

Page 22: ... encapsulated data length excluding header character Format Byte FEH Differentiate data format barcode data is always FEH Data ID The number of each data If receive the same ID more than once only the first one is valid delete the rest Barcode Type 1 byte Please refer to the Barcode Type Table Data Decoded barcode data End of Byte AEH Record data ends Reserved Byte Reserved for future use Example ...

Page 23: ... Handheld Gun Type Scanner 15 USER S MANUAL Barcode Type Table Code Value Code39 0x11 Codabar 0x01 Code128 0x03 Interleaved 2 5 0x02 Code93 0x06 UPC E 0x14 UPC A 0x24 EAN 8 0x34 EAN 13 0x44 Chinese Post Code 0x05 MSI 0x07 ...

Page 24: ...ration barcode and save the new configuration 5 To give up a configuration change power off the scanner before scanning the End of Configuration barcode or scan the Abort barcode 6 For some parameter setting such as barcode length and identifier code it is required to scan the Set barcode to save the configuration Scan barcode of the desired feature Discard the configuration Finish the configurati...

Page 25: ...meter Default Radio communication Wireless host Cradle Host Pairing mode Unlocked Data transmit Normal Radio protocol timeout 5 seconds Power off timeout 20 minutes Encryption Enable Cradle Host RS 232 communication Baud rate 9600 Parity none Data bits 8 Stop bit 1 RTS CTS off Terminator CR LF Keyboard Wedge Communication Terminator PC AT Keyboard IT keyboard Terminator Enter Alpha numeric USB Com...

Page 26: ...t Frequency Medium Duration Medium Operating Parameter Default Scan mode Trigger mode Stand mode Enable Header and trailer None Inter message delay None Inter character delay None Code Identifiers Default Identifier code as AXON standard Disable Identifier code as AIM standard Disable Code 39 identifier code M ITF 2 of 5 identifier code I Chinese post code identifier code H UPC A identifier code A...

Page 27: ...ar Expanded identifier code RX Default Data Transmit Format Code Message format EAN 13 D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 D13 EAN 8 D1 D2 D3 D4 D5 D6 D7 D8 UPCA D1 D2 D3 D4 D5 D6 D7 D8 D9 D10 D11 D12 UPCE D1 D2 D3 D4 D5 D6 D7 D8 CODE128 D1 Dx default 3 62 EAN128 C1 D1 Dx default 3 62 CODE39 D1 Dx default 3 62 CODABAR D1 Dx default 6 32 INTERLEAVED 2 5 D1 Dx default 6 32 CHINESE POST CODE D1 Dx...

Page 28: ...t to recharge and transmit data You may enable or disable the functions using the following settings Disable USB communication USB online scan disable Disable USB communication Enable USB communication USB online scan enable Wireless connection as the primary communication option to the host USB connection is only used when wireless is disconnected Set USB as the primary connection USB online scan...

Page 29: ...aired to another scanner so you must unpair the scanner before continuing 2 Power on the scanner and enable cradle host mode if necessary Cradle Host mode enable Enable cradle mode with this set 3 Use the scanner to scan the pairing barcode at the bottom of the cradle to begin pairing 3 short beeps will be heard 4 The LED indicator on the scanner will flash blue rapidly indicating search mode in p...

Page 30: ... Manuals for pairing instructions To connect a wireless device to Window based system for the first time 1 Turn on the host computer and activate its wireless connection 2 Select Add wireless device Or open the dialog BT devices and click Add 3 Power on the scanner and program it with SPP Slave mode label Scanner SPP Slave enable Enable wireless SPP Slave mode 4 On Devices tab click Add This will ...

Page 31: ...Set wireless address SPP Master only Set wireless address for SPP Master connection 4 Use the ASCII table in Programming Guide to input the 12 digit wireless address For example if the address is 011B1345600 scan 0 0 1 1 B 1 3 4 5 6 0 0 from ASCII barcode labels 5 Scan Confirm Setting to store the address Confirm Setting for address and pin code setting required 6 Setup and input the pin code if n...

Page 32: ... Enable wireless HID keyboard emulation Smart phone mode For smart phone mode BT HID MODE must also be enabled 2 Enable wireless connection on your host and follow the instructions in your host to set it to discover other wireless devices in its surrounding 3 The scanner should be on the list of discoverable devices The default name of the scanner is ZBBT You will be prompt to enter paring pin cod...

Page 33: ... Save Setting to store the pin code Set pin code Set pin code SPP Master only Confirm Setting for address and pin code setting required Please check the User s Manual from your PC for wireless address and pin code Deleting pin code To delete pin code use the Delete pin code setting Delete pin code Delete the stored pin code Reset Name To change the scanner name back to the default name ZBBT use th...

Page 34: ...mming Guide to input the name Max 12 digits 3 Scan Confirm Setting to store the new name Friendly device name set Change the display name when scanner is discovered Confirm Setting for address and pin code setting required Wireless Discovery Use the following settings to show or hide the device from wireless discovery Discover enable Make scanner visible to wireless device Discover disable Make sc...

Page 35: ...ection range the scanned data will be transferred to the host computer immediately If the scanner is out of its connecting range the scanner does not send or store any data Data transmit normal Batch mode is disabled Out of Range Scanned data are stored when scanner is out of its wireless communication range When scanner is back into its communication range or re connected the stored data are sent...

Page 36: ...rs in the bar code 2 Batch mode Note Scanner LED indicator will not flash while waiting for connection in this mode Clearing Batch Use the settings in this section to clear the stored data Clear batch data after send Saved data are cleared after they are transferred to the host Clear batch data by scanning Delete batch data label Scan this label then scan Save Setting to delete the stored batch da...

Page 37: ...ta on cradle Data is ready to be transferred upon placement on the cradle Press and hold the trigger for over 1 second to send the data Cradle radio connected is required Batch Mode Sounds Settings Use the settings in this section to setup the sound Out of range resend data with beeper sound Add beeper sound when resending data in Out of range mode Out of range resend data without beeper sound in ...

Page 38: ...ts Return cradle host to factory defaults Return to USB default Communication cradle link required Return to wand emulation default Communication cradle link required Return to RS232 default Communication cradle link required IBM PC AT PS 2 keyboard emulation Communication cradle link required Return as USB virtual COM port default Return to stand alone keyboard default Return as OPOS port default...

Page 39: ... Auto scan mode The scanner is still active after the data is transmitted but the successive transmission of the same barcode is not allowed when the trigger switch is pressed again Alternate mode The scanner illumination alternates between on and off when the trigger switch is pressed Presentation mode Also called auto trigger mode The scanner is inactive but will automatically detect barcodes pr...

Page 40: ... In this mode the scanner can not pair with another cradle Undo pairing Undo the pairing between the cradle and the scanner Scanner On Cradle sound alert enable Enable beep sound alert when scanner is placed on cradle Scanner On Cradle sound alert disable Disable beep sound alert when scanner is placed on cradle On Cradle Auto Scan mode enable Enable Auto Scan when scanner is placed on cradle On C...

Page 41: ...online scan Ignore radio communication BT HID mode BT HID mode Combo keyboard For Apple mode Must execute BT HID mode first SPP Master Slave mode Scanner SPP Master enable SPP Master Connect wireless address BxxxxxxxxxxxxT in CODE39 format Scanner SPP Slave enable Setting wireless address SPP Master only Set PIN code SPP Master only End Of Configuration ...

Page 42: ... Delete pin code Confirm Setting for address device name and pin code setting required Required Pair with slave SPP Master Discover enable Discover disable Encryption enable Encryption disable Data communication without protocol Data communication with ACK NAK protocol Data communication with Packing protocol End Of Configuration ...

Page 43: ...Send Batch Data By Scanning Label Clear batch data after send Clear batch data by scanning Delete batch data label Delete batch data Send Batch Data on line USB cable contact Send Batch data on cradle Out of range resend data with beeper sound Out of range resend data without beeper sound Send Batch Data without Beep Send Batch Data with Beep End Of Configuration ...

Page 44: ...figuration Radio protocol communication parameter Radio protocol timeout 3 sec Radio protocol timeout 5 sec Radio protocol timeout 8 sec Radio protocol timeout 10 sec Radio protocol timeout 13 sec Radio protocol timeout 16 sec Radio protocol timeout 20 sec End Of Configuration ...

Page 45: ...onfiguration Power off timeout parameter Power off timeout 5 min Power off timeout 10 min Power off timeout 20 min Power off timeout 30 min Power off timeout 1 hr Power Off timeout 2 hr Power Off timeout 4 hr Power Off timeout 6 hr Power Off timeout 8 hr End Of Configuration ...

Page 46: ...n Type Scanner 38 Start Of Configuration Power Always On Power off by scanning this label Link beeper enable Link beeper disable Power up beeper enable Power up beeper disable Same Code Delay 50 msec 100 msec 200 msec 300 msec End Of Configuration ...

Page 47: ...USER S MANUAL CS 2000 BT Wireless Handheld Gun Type Scanner 39 Start Of Configuration 400 msec 500 msec 600 msec 700 msec 800 msec 1000 msec Infinite End Of Configuration ...

Page 48: ... 2000 BT Wireless Handheld Gun Type Scanner 40 Start Of Configuration Operation Function Setting Good Read Beeper Tone Selection Medium beeper tone High beeper tone Low beeper tone Speaker disable End Of Configuration ...

Page 49: ...USER S MANUAL CS 2000 BT Wireless Handheld Gun Type Scanner 41 Start Of Configuration Beeper duration Selection Long Medium Short Ultra Short Ultra Long End Of Configuration ...

Page 50: ...ead vibrator enable Good read vibrator disable Good read beeper and vibrator enable Vibration duration 100msec Vibration duration 200msec Vibration duration 300msec Vibration duration 400msec Vibration duration 500msec Vibration duration 1 second Vibration duration 2 second Vibration duration 3 second Vibration duration 4 second Vibration duration 5 second End Of Configuration ...

Page 51: ...R S MANUAL CS 2000 BT Wireless Handheld Gun Type Scanner 43 Start Of Configuration Inter Character Delay 0 ms 2 ms 5 ms 10 ms 20 ms 50 ms Inter Message Delay 0 ms 100 ms 500 ms 1000 ms End Of Configuration ...

Page 52: ...tart Of Configuration Interface Settings 1 RS 232C Interface Setting Baud Rate 115200 19200 9600 4800 2400 1200 Parity Bit Even parity Odd parity Mark parity Space parity None parity Stop Bit 1 stop bit 2 stop bit Data Bit 7 data bit 8 data bit End Of Configuration ...

Page 53: ...ndshaking ACK NAK Xon Xoff RTS CTS Enable BEEPER ON BEL CHARACTER Ignore Beep on BEL character ACK NAK response time 300ms ACK NAK response time 2 sec ACK NAK response time 500 ms ACK NAK response time 3 sec ACK NAK response time 1 sec ACK NAK response time 5 sec ACK NAK response time infinity End Of Configuration ...

Page 54: ...f Configuration Message Terminator RS 232 message terminator none RS 232 message terminator CR LF RS 232 message terminator CR RS 232 message terminator LF RS 232 message terminator H tab RS 232 message terminator STX ETX RS 232 message terminator EOT End Of Configuration ...

Page 55: ...eyboard language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support ITALIAN send scan code Keyboard language support Switzerland send scan code Keyboard language support Belgium send scan code Keyboard language support Japanese Capital lock on Capital lock off Function key emulation enable Function key emulatio...

Page 56: ...USER S MANUAL CS 2000 BT Wireless Handheld Gun Type Scanner 48 Start Of Configuration Message Terminator Keyboard terminator none Keyboard terminator Enter Keyboard terminator H TAB End Of Configuration ...

Page 57: ...T method Keyboard language support USA Keyboard language support GERMANY Keyboard language support FRENCH send scan code Keyboard language support SPANISH send scan code Keyboard language support Japanese Keyboard language support ITALIAN Message Terminator Keyboard terminator none Keyboard terminator Enter Keyboard terminator H TAB End Of Configuration ...

Page 58: ...ted in that symbology Enable Wand output data format as CODE39 Wand emulation data output black high Scan this bar code to set quiet zones and spaces low and bars high Wand emulation data output black low Scan this bar code to set quiet zones and spaces high and bars low Idle high Idle state refers to the TTL logic level of the Wand Emulation signal when not in use Idle low Idle state refers to th...

Page 59: ...on at 1ms narrow element width Wand emulation speed medium This option allows the transmission of wand emulation at 600us narrow element width Wand emulation speed high This option allows the transmission of wand emulation at 300us narrow element width Wand emulation speed higher This option allows the transmission of wand emulation at 100 us narrow element width End Of Configuration ...

Page 60: ...ble CB05 Codabar start stop character transmission none CB06 Codabar start stop character transmission A B C D CB07 Codabar start stop character transmission DC1 DC4 CB08 Codabar start stop character transmission a t b n c d e CB09 Codabar maximum length setting CB10 Codabar minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting End Of Conf...

Page 61: ...ue Barcode Label Description CB13 No check character CB14 Validate modulo 16 but don t transmit CB15 Validate modulo 16 and transmit DC50 Codabar data redundant check off DC51 Codabar data redundant check 1 DC52 Codabar data redundant check 2 DC53 Codabar data redundant check 3 End Of Configuration ...

Page 62: ...1 Code 39 disable RC13 Pharmacode enable RD13 Pharmacode disable DC00 Code 39 data redundant check off DC01 Code 39 data redundant check 1 DC02 Code 39 data redundant check 2 DC03 Code 39 data redundant check 3 3901 Standard code 39 3902 Full ASCII code 39 3903 Code 39 start stop character transmission 3904 Code 39 start stop character without transmission End Of Configuration ...

Page 63: ...t 3906 Code 39 check digit calculate but without transmit 3907 No check character 3908 Code 39 maximum length setting 3909 Code 39 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 3912 Code 32 Italian pharmacy transmit A character 3913 Code 32 Italian pharmacy without transmit A character End Of Configuration ...

Page 64: ...93 data redundant check 1 DC32 Code 93 data redundant check 2 DC33 Code 93 data redundant check 3 9301 Code 93 maximum length setting 9302 Code 93 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 9303 Code 93 check digit calculate but without transmit 9304 Code 93 check digit not calculate and without transmit 9305 Code 93 check digit...

Page 65: ...28 disable DC40 Code 128 data redundant check off DC41 Code 128 data redundant check 1 DC42 Code 128 data redundant check 2 DC43 Code 128 data redundant check 3 1803 No check character 1804 Calculate but not transmit 1805 Calculate and transmit 1806 Code 128 maximum length setting 1807 Code 128 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length...

Page 66: ... post code disable DC60 Chinese post code data redundant check off DC61 Chinese post code data redundant check 1 DC62 Chinese post code data redundant check 2 DC63 Chinese post code data redundant check 3 SZ01 Chinese post code maximum length setting SZ02 Chinese post code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting End Of Config...

Page 67: ...th setting MS02 MSI Plessy minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting MS03 MSI Plessy double check digit calculate but not transmit MS04 MSI Plessy double check digit without calculate and transmit MS05 MSI Plessy double check digit calculate but only first digit transmit MS06 MSI Plessy double check digit calculate and both tra...

Page 68: ...setting 1102 Code 11 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting 1103 Code 11 one check digit verification 1104 Code 11 two check digit verification 1105 Two Check for Code 11 check digit if code length is longer than 10 characters 1106 Disable verification 1107 Code 11 check digit transmitted 1108 Code 11 check digit not transmi...

Page 69: ...enable RD04 ITF 2 of 5 disable RC09 IATA code enable RD09 IATA disable DC80 ITF 25 data redundant check off DC81 ITF25 data redundant check 1 DC82 ITF25 data redundant check 2 DC83 ITF25 data redundant check 3 IT03 ITF 2 of 5 no check character IT04 ITF 2 of 5 check digit calculate and transmit IT05 ITF 2 of 5 check digit calculate but without transmit End Of Configuration ...

Page 70: ...ription IT01 ITF 2 of 5 code maximum length setting IT02 ITF 2 of 5 code minimum length setting IT06 ITF 2 of 5 one fixed length setting IT07 ITF 2 of 5 two fixed length setting SET Confirm to save this setting required for reading full ASCII table and length setting IT08 ITF 2 of 5 length variable End Of Configuration ...

Page 71: ...ard 2 of 5 code disable D051 Standard 2 of 5 code maximum length setting D052 Standard 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D053 Standard 2 of 5 code no check character D054 Standard 2 of 5 code check digit calculate and transmit D055 Standard 2 of 5 code check digit calculate but without transmit End Of Config...

Page 72: ...2 of 5 code disable D251 Industrial 2 of 5 code maximum length setting D252 Industrial 2 of 5 code minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D253 Industrial 2 of 5 code no check character D254 Industrial 2 of 5 code check digit calculate and transmit D255 Industrial 2 of 5 code check digit calculate but without transmission End...

Page 73: ...RC11 EAN convert to ISSN ISBN enable RD11 EAN convert to ISSN ISBN disable RC03 UPC EAN JAN enable RD03 UPC EAN JAN disable UE01 UPC EAN JAN all enable UE02 EAN 8 or EAN 13 enable UE03 UPC A and EAN 13 enable UE04 UPC A and UPC E enable UE05 UPC A enable UE06 UPC E enable UE07 EAN 13 enable UE08 EAN 8 enable UE09 UPC EAN Addendum disable End Of Configuration ...

Page 74: ...format disable UE15 Force UPC A to EAN 13 format enable UE16 Force UPC A to EAN 13 format disable UE44 Force EAN 8 to EAN 13 format enable UE45 Force EAN 8 to EAN 13 format disable UE17 Transmit UPC A check digit enable UE18 Transmit UPC A check digit disable UE19 Transmit UPC E leading character enable UE20 Transmit UPC E leading character disable UE21 Transmit UPC E check digit enable UE22 Trans...

Page 75: ...ck digit disable UE27 Transmit UPC A leading character enable UE28 Transmit UPC A leading character disable UE30 Add on format with separator UE31 Add on format without separator UE60 EAN 13 country code first 0 can be transmitted UE61 EAN 13 country code first 0 can t be transmitted UE66 EAN 13 with first 0 ID code same as UPC A UE67 EAN 13 with first 0 ID code same as EAN 13 DC10 UPC A data redu...

Page 76: ...dundant check 1 DC16 UPC E data redundant check 2 DC17 UPC E data redundant check 3 DC20 EAN 13 data redundant check off DC21 EAN 13 data redundant check 1 DC22 EAN 13 data redundant check 2 DC23 EAN 13 data redundant check 3 DC24 EAN 8 data redundant check off DC25 EAN 8 data redundant check 1 DC26 EAN 8 data redundant check 2 DC27 EAN 8 data redundant check 3 UE32 EAN UPC add on none mandatory U...

Page 77: ...plement requirement not sent for other UE38 EAN UPC addon mandatory for 978 977 bookland Supplement requirement optional for other UE42 EAN UPC addon mandatory for 491 Japanese bookland Supplement requirement not sent for other UE43 EAN UPC addon mandatory 491 Japanese bookland Supplement requirement optional for other End Of Configuration ...

Page 78: ...ndheld Gun Type Scanner 70 Start Of Configuration 12 Telepen Parameter Setting Barcode Value Barcode Label Description RC25 Telepen enable RD25 Telepen disable TE03 Telepen numeric mode enable TE04 AIM Telepen enable End Of Configuration ...

Page 79: ...able RD12 Matrix 2 of 5 disable D151 Matrix 2 of 5 maximum length setting D152 Matrix 2 of 5 minimum length setting SET Confirm to save this setting required for reading full ASCII table and length setting D153 Matrix 2 of 5 no check character D154 Matrix 2 of 5 check digit calculate and transmit D155 Matrix 2 of 5 check digit calculate but without transmission End Of Configuration ...

Page 80: ...Limited Formally RSS Limited GS1 DataBar Limited Group 3 GS1 DataBar Expanded Formally RSS Expanded GS1 DataBar Expanded GS1 DataBar Expanded Stacked GS1 DataBar Omnidirectional Formally RSS 14 Barcode Value Barcode Label Description RC15 GS1 DataBar Omnidirectional enable RD15 GS1 DataBar Omnidirectional disable SS00 Transmit GS1 DataBar Omnidirectional check digit SS01 Do not transmit GS1 DataBa...

Page 81: ...arcode Value Barcode Label Description RC16 GS1 DataBar Limited enable RD16 GS1 DataBar Limited disable SS10 Transmit GS1 DataBar Limited check digit SS11 Don t transmit GS1 DataBar Limited check digit SS12 Transmit GS1 DataBar limited application ID 01 SS13 Do not transmit GS1 DataBar limited application ID End Of Configuration ...

Page 82: ...aBar Expanded enable RD17 GS1 DataBar Expanded disable SS07 GS1 DataBar Expanded EAN 128 emulation enable SS06 GS1 DataBar Expanded EAN 128 emulation disable SS08 GS1 DataBar Expanded check digital enable SS09 GS1 DataBar Expanded check digital disable SS16 Transmit GS1 DataBar Expanded application ID 01 SS17 Do not transmit GS1 DataBar Expanded application ID End Of Configuration ...

Page 83: ...tandard IS03 Enable identifier code table as AIM standard CI01 Code 39 identifier code setting CI02 ITF 2 of 5 identifier code setting CI03 Chinese Post Code identifier code setting CI04 UPC E identifier code setting CI05 UPC A identifier code setting CI06 EAN 13 identifier code setting CI07 EAN 8 identifier code setting SET Confirm to save this setting required for reading full ASCII table and le...

Page 84: ...ier code setting CI12 GS1 DataBar Omnidirectional identifier code setting CI13 GS1 DataBar Limited identifier code setting CI14 GS1 DataBar expanded identifier code setting CI15 Industrial 2 of 5 identifier code setting CI16 Code 11 Identifier code setting CI17 Standard 2 of 5 identifier code setting CI18 Matrix 2 of 5 identifier code setting SET Confirm to save this setting required for reading f...

Page 85: ...Label Description CP11 Add code length as header enable 2 digits CP12 Add code length as header disable 2 digits HT01 Header Preamble HT02 Trailer Postamble HT03 Truncate header character HT04 Truncate trailer character SET Confirm to save this setting required for reading full ASCII table and length setting End Of Configuration ...

Page 86: ...row 05 Full ASCII DC4 Function key F4 14 Full ASCII ACK Function key Down arrow 06 Full ASCII NAK Function key F5 15 Full ASCII BEL Function key Left arrow 07 Full ASCII SYN Function key F6 16 Full ASCII BS Function key Backspace 08 Full ASCII ETB Function key F7 17 Full ASCII HT Function key TAB 09 Full ASCII CAN Function key F8 18 Full ASCII LF Function key Enter alpha numeric 0A Full ASCII EN F...

Page 87: ...tion key ALT L 1F Full ASCII 2E Full ASCII SP 20 Full ASCII 2F Full ASCII 21 Full ASCII 0 30 Full ASCII 22 Full ASCII 1 31 Full ASCII 23 Full ASCII 2 32 Full ASCII 24 Full ASCII 3 33 Full ASCII 25 Full ASCII 4 34 Full ASCII 26 Full ASCII 5 35 Full ASCII 27 Full ASCII 6 36 Full ASCII 28 Full ASCII 7 37 Full ASCII 29 Full ASCII 8 38 Full ASCII 2A Full ASCII 9 39 Full ASCII 2B Full ASCII 3A Full ASCI...

Page 88: ...Full ASCII 3E Full ASCII M 4D Full ASCII 3F Full ASCII N 4E Full ASCII 40 Full ASCII O 4F Full ASCII A 41 Full ASCII P 50 Full ASCII B 42 Full ASCII Q 51 Full ASCII C 43 Full ASCII R 52 Full ASCII D 44 Full ASCII S 53 Full ASCII E 45 Full ASCII T 54 Full ASCII F 46 Full ASCII U 55 Full ASCII G 47 Full ASCII V 56 Full ASCII H 48 Full ASCII W 57 Full ASCII I 49 Full ASCII X 58 Full ASCII J 4A Full A...

Page 89: ...A Full ASCII 5C Full ASCII k 6B Full ASCII 5D Full ASCII l 6C Full ASCII 5E Full ASCII m 6D Full ASCII _ 5F Full ASCII n 6E Full ASCII 60 Full ASCII o 6F Full ASCII a 61 Full ASCII p 70 Full ASCII b 62 Full ASCII q 71 Full ASCII c 63 Full ASCII r 72 Full ASCII d 64 Full ASCII s 73 Full ASCII e 65 Full ASCII t 74 Full ASCII f 66 Full ASCII u 75 Full ASCII g 67 Full ASCII v 76 Full ASCII h 68 Full A...

Page 90: ...nner 82 Start Of Configuration Full ASCII Code 39 Table continued Code 39 ASCII Hexa code Code 39 ASCII Hexa code Full ASCII x 78 Full ASCII 7C Full ASCII y 79 Full ASCII 7D Full ASCII z 7A Full ASCII 7E Full ASCII 7B Full ASCII DEL 7F End Of Configuration ...

Page 91: ...ow to enable USB virtual COM port 1 Connect the handheld scanner and the host e g a PC with a USB interface cable 2 Enable USB virtual COM port with programming barcode on page 29 3 After the programming the host would request driver installation Browse your files to locate the driver and start installation 4 The USB virtual COM port is ready for use after driver installation ...

Page 92: ... a 0 in the front Example If the barcode length is 4 to 12 digits the steps would be as below End Set up barcode length Start Set up minimum barcode length Start of Configuration Set up maximum barcode length End of Configuration Scan the Start of configuration barcode Scan the Set barcode to save this Scan the Min barcode Set the Max barcode Set up the second digit 2 Scan the first digit 0 Scan t...

Reviews: