ARCHITECTS & ENGINEERS SPECIFICATION
The single gang mount interface unit shall have an OLED display screen and a pushbutton encoder knob and secondary pushbutton for
controls.
The device shall support mounting the mounting of multiple units side by side in a multi-gang wall box or one unit in a single gang US wall
box.
The unit shall accept either IEEE 802.3af standard PoE from an IEEE 802.3af PoE compliant network switch or mid-span injector.
The unit shall support a flexible programming interface for targeting control of 3
rd
party AV systems and products.
The unit shall include a software plugin for simple interfacing with QSC Q-SYS based DSP systems.
The network control interface shall be compliant with the RoHS, WEEE and REACH directives.
The network control interface unit shall be Compliant with the EMC/ESD requirements for FCC and CE.
The unit shall be the Attero Tech Axon C1 product.