background image

Index of Contents

2

EU Declaration of Conformity

EU Declaration of Conformity 

02

What’s Included 

03-04-05-06

General Instruction for 230V Machines 

06

Specific Safety for Dust Extractors 

07

Specification 07
Assembly 08-09-10-11-12-13-14
Illustration and Parts Description 

15-16-17

Operating Instruction 

18-19

Ducting System 

20

Maintenance 21
Weekly LEV System Maintenance Log 

22-23

LEV Testing 

24

Extraction Accessories 

24

Exploded Diagrams/Parts Lists 

25-26

Wiring Diagram 

27

The symbols below advise the correct safety procedures when using this machine.

Fully read manual

and safety instructions

before use

Eye protection

should be worn

Ear protection

should be worn

HAZARD

Dust mask

should be worn

 

Cert No: CT-90HCK

Axminster Tools & Machinery Ltd
Axminster Devon 
EX13 5PH UK
axminster.co.uk

Type

Dust Extractor

Model

AT340E

and conforms to the machinery example for which the 
EC Type-Examination Certificate No 1002-CI-32016/META-2016002-A1
has been issued by META INTERNATIONAL CO., LTD
at: No. 117, In. 400.sec.3, Yatan td., Daya Dist., Taichung City 428, Taiwan 

and complies with the relevant essential health and safety requirements. 

2006/42/EC
2014/35/EU
EN ISO 12100:2010
EN 60204-1:2006+A1: 2009+AC:2010

declares that the machinery described:-

This machine complies with the following directives:

EU Declaration of Conformity

Signed

Andrew Parkhouse
Operations Director

Date: 03/05/2016 

Summary of Contents for Trade AT340E

Page 1: ...AT340E 3HP Dust Extractor AT M 14 09 2019 REF 102650 Code 102179 Original Instructions ...

Page 2: ...tructions before use Eye protection should be worn Ear protection should be worn HAZARD Dust mask should be worn Cert No CT 90HCK Axminster Tools Machinery Ltd Axminster Devon EX13 5PH UK axminster co uk Type Dust Extractor Model AT340E and conforms to the machinery example for which the EC Type Examination Certificate No 1002 CI 32016 META 2016002 A1 has been issued by META INTERNATIONAL CO LTD a...

Page 3: ...s d 2 Thin Washers e 2 Larger Washer f 1 Small Phillips Screw g 30 5 16 UNC Hex Bolts Short h 4 5 16 UNC Hex Bolts Long i 4 5 16 UNC Nuts j 8 5 16 UNC Hex Bolts Large Washers Nuts k 2 UNC Hex Countersink Screws l 2 1 2 Large Hex Bolt m Extactor Fixings Extactor Parts NOTE Please read the Instruction Manual prior to using your new machine As well as the operating procedures for your new machine the...

Page 4: ...What s Included 4 5 7 6 8 9 11 18 10 ...

Page 5: ...What s Included 5 12 14 13 15 16 17 Continues Over ...

Page 6: ...rect speed and function set Ensure you are comfortable before you start work balanced not reaching etc Wear appropriate safety clothing goggles gloves masks etc Wear ear defenders at all times If you have long hair wear a hair net or helmet to prevent it being caught up in the rotating parts of the machine Consideration should be given to the removal of rings and wristwatches Consideration should ...

Page 7: ...hine relies on its ability to blow air through the filter to generate good suction If the particle filter starts to clog this reduces the air flow and hence the machine becomes less efficient The particle filter can be cleaned by using an M class vacuum cleaner clean the inside of the filter BE AWARE that in dry air periods or areas the movement of the air through the machine can generate static e...

Page 8: ...SPONSIBLY Having unpacked the boxes put all components where they are readily to hand 1 Locate the two extractor bases 1 2 tube support bars 3 upright supports 4 castor wheels 10 and the 5 16 unc Hex bolts h short Put the two extractor bases together and line up the pre drilled holes Secure the bases with four Hex bolts h two on top and one either side of the base assembly see figs 01 02 03 Fig 01...

Page 9: ...up the four holes in the two upright supports with the threaded holes to the rear of the extractor base Screw the hex bolts down through the upright supports into the base and lightly tighten see fig 11 12 13 7 Locate the tube support bars 3 and six Hex bolts h Line up the two pre drilled holes in the support bars angle brackets with the holes to the sides of the base assembly secure in place with...

Page 10: ...ports 3 are to the outside of the extractor assembly 13 not tucked inside the housing NOTE YOU WILL REQUIRE ASSISTANCE FOR THE NEXT STEPS Fig 18 19 9 Insert four Hex bolts h through the extractor s mounting brackets and tighten Line up the holes in the nearest tube support angle bracket 3 with the threaded holes to the side of the extractor s housing and secure in place with two Hex bolts i Secure...

Page 11: ...e collector assembly 12 and secure in place with two 5 16 Hex bolts h see fig 26 Fig 24 25 k Square outlet Fig 26 13 Introduce the remaining Hex bolts k through the seven holes in the extractor collector s square outlets and securely tighten with two spanners see figs 27 28 29 14 Put to hand the tube handle 7 the two Hex countersink screws l and the 5mm Hex key a Line up the holes in the tube hand...

Page 12: ...bolts i long and four 5 16 nuts j Line up the holes in the tube support angle bracket 3 with the threaded holes to the side of the extractor s housing and secure in place with two Hex bolts i see fig 36 37 Fig 36 37 i h 3 17 Slot the dust defector assembly up through the centre of collector 12 introduce the two pre drilled holes in the angle bracket over the threaded studs i and secure in place wi...

Page 13: ...ack the paper backing position the end of band up against the underside of the upper lip on the extractor housing and firmly press down to secure in place Carefully peel back the backing guiding the seal band round the extractor until it overlaps using a pair of scissors cut off any excess see figs 44 45 46 22 Go around pressing down the band to make sure it s stuck firmly down Repeat step 21 for ...

Page 14: ...er and latch them down to hold and to seal the filters units see figs 51 52 Fig 51 52 26 Locate the inlet manifold 6 and the small Phillip screw g Insert the manifold over the extractor s inlet and line up the threaded hole in the inlet with cutout slot in the manifold Secure the manifold in place with the Phillips screw see fig 53 54 27 Finally go round and check all fixing are securely tight Fig...

Page 15: ...ption 15 Filter cartridge Shaker paddle operating handles Tube handle Motor assembly Upright support Wheel Castor wheel Tube support bar Bag retaining belt Filter retaining belt Inlet manifold Base Filter dust bag AT340E FrontView ...

Page 16: ...ration and Parts Description 16 Extractor assembly NVR switch assembly Filter cartridge Tube support bar Base Wheels Upright supports Filter dust bag Motor air vent Tube handle Collector unit AT340E Rear View ...

Page 17: ...er paddle operating handles to remove build up of dust inside the filter cartridge Filter retaining belt clip NVR switch assembly with O indicating OFF and I indicating ON For emergencies SLAP the shroud down to STOP the machine Motor air vents ...

Page 18: ... ON OFF THE EXTRACTOR BY THE NVR CONTROL SWITCH NOT THE MAINS SWITCH Connect the extraction hose s to the adaptor outlet DISCONNECT THE POWER SUPPLY FROM THE MAINS After a period of time dust sawdust and shavings can build up causing blockages and reduced suction performance Carry out the following checks to keep your extractor working at peak performance Check the filter for signs of buildup of s...

Page 19: ...dust bag below The defector plate shown above and to the left is designed to defect dust and large particles down into the dust bag This helps to reduce build up of material inside the micro filter and makes it easier when cleaning Fine dust defected up inside filter Large particles defected down into dust bag Operating Instructions 19 ...

Page 20: ... pressure inside the ducting draws air into the system Incorrect sizing of the duct too many bends coupled to lots of flexible hose induces losses into the system and in badly designed systems this is akin to leaving the hand brake on in a vehicle machines count the number of extraction ports per size multiply the number of each size by the volume of air required Then add the results per outlet si...

Page 21: ...lection bag for wear and tear especially around the neck of the retaining belt If wear or fraying is occurring replace the bag Check the motor for dust sawdust shavings etc build up If this has occurred clean with a vacuum cleaner see fig 58 Move the shaker paddle handle back and forth to remove any built up dust and debris from inside the filter Monthly Remove the filter securing belt and remove ...

Page 22: ...eration of all blastgate controls Check filter s for damage and condition Check filter shakers if fitted and clean filters Check waste collector s for damage and condition Empty waste collectors if necessary Comments 1 2 3 4 5 6 7 8 9 10 11 12 REMOVE AND CLEAN FILTERS 13 14 15 16 17 18 19 20 21 22 23 24 REMOVE AND CLEAN FILTERS 25 26 27 28 29 30 31 ...

Page 23: ...r s for damage and condition Check filter shakers if fitted and clean filters Check waste collector s for damage and condition Empty waste collectors if necessary Comments 32 33 34 35 36 REMOVE AND CLEAN FILTERS 37 38 39 40 41 42 43 44 45 46 47 48 49 REMOVE AND CLEAN FILTERS 50 51 52 Nearly 14 months it is now a legal requirement to have your system tested and certified 53 54 55 56 57 58 59 60 ...

Page 24: ...oyee safety representatives All of these groups need to work together to provide maintain and use effective LEV and to reduce exposure from inhalation of hazardous substances The book contains information about the roles and legal responsibilities of suppliers and of their clients as employers competence principles of good design practice for effective LEV hoods and their classification ducts air ...

Page 25: ...x1 2 44 16 Handle 1 17 Tube Cap 1 2 18 Hex Bolts 5 16 x1 1 4 2 19 2 5 Caster 4 20 Bearing Wheel 7 2 21 Hex Bolts 1 2 x 4 1 2 2 22 Luck Nuts 1 2 2 23 Key 1 24 Flange Nuts 5 16 4 25 Plastic Washer 2 26 Washer 1 2 x 19 2 27 Motor Cord 1 28 Switch 1 29 Motor Packing 1 30 Washer 1 2 x34 2 31 Inlet 8 x 6 1 33 Phillips Screw 3 16 x3 8 1 34 Main Housing left 1 35 Back Base 1 36 Canister Filter 2 37 Flange...

Page 26: ...1 1 3 5 16 Hex Nut 004 0904 5 4 5 16 x 1 2 Flange Bolt 004 0481 3 5 5 16 x 3 4 Flange Bolt 004 0483 2 Deflector Collector Units NO DESCRIPTION PART NO QTY 1 Barrel Body 009 0201 1 2 Separator 037 0599 1 3 Separator Hanger 045 0141 1 4 5 16 Hex Nut 004 0904 5 5 5 16 x 1 2 Flange Bolt 004 0481 3 6 5 16 x 3 4 Flange Bolt 004 0483 2 ...

Page 27: ...Wiring Diagram 27 ...

Page 28: ...02 96 EC on waste electrical and electronic equipment and its implementation in accordance with national law electric tools that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility Only for EU countries The Axminster guarantee is available on Craft Trade Engineer AirTools CNCTechnology Series machines It s probably the mo...

Reviews: