17
5.2 The operating of manometer
(
Fig.13
)
D. Manometer:
This manometer is not used to measure the pressure, is mainly used to observe whether there is
abnormal pressure fluctuations.
Every time, when you power this machine and adjust to the frequency that you needed, turn the
manometer ring, make the “arrow mark” match pointer.
If you find the reading has increased, there could be a blockage in the ducting system or
extractor unit, check the following:
Check the hoses for blockages.
If you find the reading has decreased, check the following:
Check the hoses are secure, “NOT LOOSE”, which will lead to air leakages.
Check hoses for splits and cracks.
Usually you need to remove dust extractor adaptor to check whether it is blockage.
5.3 Clean the dust bin.
When the buzzer sounds, you should clean up the dust bin.
Rotate the knobs as the arrow indicates
(see Fig.6)
to open the door. Release the dust bin
(see
Fig.7)
, you can slide the dust bin out.
You should clear the dust bin every day.
5.4 General operation
Please follow these steps each time you start operating the machine:
1. Check the machine, make sure the dust bin is locked.
2. Connect the machine to the power 220V/1PH/60Hz.
3. Turn on power switch, the buzzer will sound and the screen of the control panel will be lighted.
4. Press the green button to start this machine, the initial frequency is 40Hz, you can adjust the
frequency from 40Hz-75Hz. Press the red button to stop this machine.
5. When the collection box is full, the buzzer will sound, you can open the front door, pull out the
dust bin and empty it.