REAR PANEL CONNECTIONS
RCA
RCA
Zone 1 line outputs
Mono Utility input
Speaker Outputs
Pre – out Source select
Zone 2
Zone 1
Speaker D Speaker C Speaker B Speaker A
2 way connector 9 Pin connector
Preset Utility
RS232
20 way Header
10 way connector
IEC Fused
RCA Expansion Bus Controller connections AC power socket
Audio Source
Line Level Inputs
3.5mm phono
IR output
Audio Source Inputs
CD, TAPE, TUNER, AUX & Utility are common to all zones.
The utility input is mono and connects to both left and right channels. Typical applications are
paging, or where a mono source is required (AM radio)
Line Outputs
SOURCE SELECT is the Zone 1 pre-fader output - independent of the volume control.
A typical application for this output is where speakers have volume pads installed and a slave
amplifier is required to operate the network at full power.
PRE-OUT is the Zone 1 post fader output
–
Output level is dependant on the volume control.
The output is muted when Zone 1 is muted
.
PRE-OUT may be used to drive a high power Slave amplifier or Active Sub-Woofer.
IR Out
A 3.5mm phono socket provides direct connection for IR emitters. The output is individually
buffered and current limited, this ensures that a damaged emitter does not short out the IR
system.
Expansion Bus
Axium amplifiers may be connected together via a 20 way IDC ribbon cable connection.
This simplifies the Audio source component connections. – CD, TAPE, TUNER, AUX & Utility are
connected to only one Axium amplifier!
The summed Amp-On output, Axium Bus, and buffered IR input are linked through the Bus.
Axium Bus is a 2 wire serial communication interface which provides inter-amplifier and controller
monitoring and control.
6