Axium Bus  

Axium Bus provides inter amplifier & Keypad control and monitoring.  

The Bus is protected from shorts to both 0V and +12VDC. 

 

 

Bass, Treble, Balance, and Loudness controls 

Bass, Treble, and Balance controls may be accessed via the front panel or RS232. The 

loudness control - which is a low frequency boost whose level is dependent on volume 
– is controlled via the AMPCTRL set up utility (RS232) 

 

 

Expansion Bus 

Data, IR, Amp-On & Audio Sources are interconnected via the expansion bus  

to other Axium amplifiers, thus simplifying the Axium amplifier stack wiring. 

The expansion bus uses the simple 20-way ribbon cable connector system 
 

 

32 Zones 

32 zones of control is available. On the AX250i each Zone must be different, however 

in a multiple amplifier stack same Zone amplifiers are possible – they simply mimic 

every parameter. 

 

 

Zone Tracking 

A Zone may be programmed to track one other Zone. When Zone tracking is selected, 
the source selection is tied together, but Standby, Mute, and volume control are 

independent. This is useful for closely coupled audio areas where it is advantageous to 

have different volume control but the same source. 
  

 

Maximum volume limiting 

A volume limit may be set on any Zone, typically this is to prevent reckless use of the 
system, or prevent destruction of speakers when powered by a slave amplifier. 

 

 

Global IR commands 

There is a range of Global IR commands available for turning All amplifiers either On, 

Off, or selecting various audio sources. There are also Force and Release Preset 

commands that invoke a user programmed Amplifier preset.   
 

 

Global Preset

 

 

One Preset may be programmed for every Zone, wherein any controlled parameter 

may be set. A Preset may be invoked either by the Preset IR command, RS232, or by 

a contact closure at the panels “preset input utility” connector on the rear panel. When 
a preset is invoked all Zones go to their programmed preset state. Upon release from 

the preset the amplifier Zone returns to it’s previous state. A typical application is 

phone paging. 

 

 

Firmware upgradeable  

The AX250i’s microcontroller may be updated with the latest operational firmware via 
the RS232 port and a boot-loader program. The ability to enhance the functionality of 

installed Axium product’s provides a degree of future proofing, and flexibility. 

 

 

Toroidal transformer power supply 

An impressive toroidal transformer ensures stable power supply performance and 

minimal magnetic field interference.   
 

 

Restore factory defaults 

Remove AC power, push and hold down Function & Tuner Keys and reconnect AC 
power. The Amplifier will be reset to factory defaults, and memory cleared. 

 

Summary of Contents for AX250i

Page 1: ...INSTALLATION OPERATION MANUAL AX250i Two Zone Two Stereo Pre Amplifiers Amplifiers With RS232 Keypad IR Control Total In Home Connectivity ...

Page 2: ...products are built to the highest standards of quality and reliability To view Axium s product line of Multizone Amplifiers controllers accessories please visit the Website at www axium co nz You may also download the latest control software Table Of Contents INTRODUCTION 1 FEATURES 2 INSTALLATION QUIDE 4 FRONT PANEL OPERATION 5 REAR PANEL CONNECTIONS 6 SPECIFICATIONS 8 APPENDIX1 RS232 PROTOCOL 9 ...

Page 3: ...imit setting zone tracking See the features section of the manual A utility program called AMPCTRL is available from the Axium website this gives users complete access and control of all Axium networked components and even provides the ability to schedule events from your personal computer Axium Multizone amplifiers may be interconnected via the expansion bus providing up to 32 zones of control an...

Page 4: ... and 12VDC outputs on the rear panel connector The output s are protected against shorts and back EMF voltage surges which may occur if powering a relay Summed Amp On A Summed Amp On 12VDC output is provided on the rear panel connector This is typically used to switch the Audio source component s AC power If any amplifier Zone or Speaker output in an Axium amplifier stack is ON then this output wi...

Page 5: ...lly this is to prevent reckless use of the system or prevent destruction of speakers when powered by a slave amplifier Global IR commands There is a range of Global IR commands available for turning All amplifiers either On Off or selecting various audio sources There are also Force and Release Preset commands that invoke a user programmed Amplifier preset Global Preset One Preset may be programme...

Page 6: ...an flow freely and escape from the amplifier surroundings Failure to do so may cause intermittent channel cutout and reduced life expectancy 3 Under no circumstances should the speaker output terminals of the unit be short circuited or connected to another output 4 Never plug the RS232 cable into the unit while power is connected 5 Never short the 10 way controller connector terminals These should...

Page 7: ...utton until the BASS indicator LED is illuminated You can then increase or decrease the BASS by pressing the VOL UP increase or DOWN decrease The FUNCTION level value is indicated on the 2 digit display The Zone is selectable between 0 31 and must be set in memory by pressing the SELECT button FUNCTION mode is terminated after 4 seconds of inactivity or by toggling past the last FUNCTION ZONE STAN...

Page 8: ... have volume pads installed and a slave amplifier is required to operate the network at full power PRE OUT is the Zone 1 post fader output Output level is dependant on the volume control The output is muted when Zone 1 is muted PRE OUT may be used to drive a high power Slave amplifier or Active Sub Woofer IR Out A 3 5mm phono socket provides direct connection for IR emitters The output is individu...

Page 9: ...On 12V This is used to switch power sockets for connecting AC power to Audio source components i e CD players Tuners etc Amp ON A If Speaker A Zone 1 is ON then output will be 12V Current limited 25mA Amp On B If Speaker B Zone 1 is ON then output will be 12V Current limited 25mA Amp On C If Speaker C Zone 2 is ON then output will be 12V Current limited 25mA Amp On D If Speaker D Zone 2 is ON then...

Page 10: ...s control range 12db Treble control range 12db Balance control range 19db Loudness boost Gain 50db 6db 40Hz Volume control range 86db 0db 2 5db steps Mute attenuation 100db Amplifier Output power 8 ohm load 50W RMS Output power 4 ohm load 75W RMS Slew Rate 10V µs THD 8ohm load 1KHz 5Watt 0 01 IR range 9 m 30degrees off horizontal axis Dimensions Width 435mm 17 Height 112mm 4 2 5 Depth 340mm 13 2 5...

Page 11: ...byte Zone Axium amplifiers and keypads are encoded with up to 32 zones 00 31 All amplifier zones may be addressed by sending the FF characters Data Command Content Standby 00 Standby A OFF 01 Standby A ON 02 Standby B OFF 03 Standby B ON Mute 00 Mute 01 Un mute Source Selection 00 Select CD 01 Select Tape 02 Select Tuner 03 Select Auxiliary 04 Select Mono utility input Volume 00 A0 range Bass F4 0...

Page 12: ...one X Example strings 010801 Standby A ON command for Zone 8 060002 2db Treble setting on Zone 0 033102 Tuner source selection on Zone 31 0B0311 Volume down continuous push on Zone 3 keypad Keypad key codes An Axium Keypad may be directed to emit its learnt IR commands via RS232 control This is achieved by sending a Cause key press on Keypad command followed by the zone and the Keypad key code dat...

Page 13: ...cally or as single events A keypad Macro may also be programmed as part of the Schedule An Axium Keypad connected to an amplifier may be controlled causing the keypad to emit it s learnt IR strings Thus Audio Source CD Tuner etc control may be achieved via the AMPCTRL program The Keypads programming file may be imported from AxiumIR Keypad and Remote control program providing button ID s For a ful...

Reviews: