AXITEC INSTALLATION 

– USA 170727 

1.3 

CAUTIONS 

 

Use a module for its intended purpose only. 

 

Do not treat any portion of the module with paint or adhesives, to avoid damage to the module, 

in

operable conditions, or reducing the module’s functionality. 

 

Careful attention to the design of the PV system and electrical capacity of system components is 

required (especially the inverter) for the reason that this module may generate more than 120% of 

its’ STC rated power (Pmax). 

 

This additional power depends upon the level of incident light irradiance (Aledo) available to the 

backside of the module, and can be increased or decreased depending upon site characteristics 

and installation design. 

 

Please do

n’t uses artificially concentrate sunlight on the modules. 

INSTALLATION AND OPERATION 

 

Systems must be installed by qualified and experienced personnel only. 

Do not step on the module. Although AXITEC LLC modules are quite rugged, the glass may be 

broken (and the module will no longer work properly) if it is dropped or hit by tools or other objects. 

Sunlight shall not be concentrated on the module. 

 

The module frames is made of anodized aluminum, and therefore corrosion can occur if the module 

is placed in a salt water environment with contact to a rack of an- other type of metal (Electrolytic 

Corrosion). If required, PVC or stainless steel washers can be placed between the solar module 

frame and support structure to prevent this type of corrosion. 

 

Any module support structures that are to be used to support AXITEC LLC solar module must be 

wind rated and approved for use by the appropriate local and civil codes prior to installation. 

MECHANICAL INSTALLATION 

There are different ways to attach the solar module. The solar module of AXITEC LLC can be attached and 

installed with mounting holes or clamps. The module can be installed in both landscape and portrait modes. 

Figure 1 shows the different mounting options with the appropriate snow loads. 

 

 

 

 

 

 

 

 

Summary of Contents for 60-CELL

Page 1: ...1 12 AXITEC INSTALLATION USA 170727 Installation Manual AXITEC SOLAR MODULES ...

Page 2: ...ONS 5 2 INSTALLATION AND OPERATION 5 3 MECHANICAL INSTALLATION 5 3 1 60 CELL MODULES 6 3 2 72 CELL MODULES 7 3 3 MOUNTING WITH BOLTS 8 3 4 MOUNTING WITH CLAMPS 9 3 5 GROUNDING 9 4 ELECTRICAL INSTALLATION 9 4 1 GENERAL WIRING 9 4 2 MODULE WIRING 10 4 3 ARRAY WIRING 10 5 JUNCTION BOX AND TERMINATION 10 6 MAINTENANCE 11 7 SPECIFICATION 11 7 1 ELECTRICAL SPECIFICATION Typical 11 7 2 GENERAL SPECIFICAT...

Page 3: ...o make changes to the product specifications or this manual without prior notice Without any prior written authorization AXITEC LLC will not accept any returned modules GENERAL INFORMATION The installation of solar modules must only be performed by skillful and qualified professionals SAFETY Follow all permission installation and inspection requirements Must contact the appropriate authorities to ...

Page 4: ...dry modules and tools Do not break the glass surfaces of modules Do not drop a module Do not allow children and unauthorized persons near the installation site or storage area of modules All modules have been complete grounding to earth with electrical insulation Do not open the cover of the junction box Do not disassemble the module or remove any part installed by the manufacturer Wear suitable p...

Page 5: ...dule Although AXITEC LLC modules are quite rugged the glass may be broken and the module will no longer work properly if it is dropped or hit by tools or other objects Sunlight shall not be concentrated on the module The module frames is made of anodized aluminum and therefore corrosion can occur if the module is placed in a salt water environment with contact to a rack of an other type of metal E...

Page 6: ...6 12 AXITEC INSTALLATION USA 170727 3 1 60 CELL MODULES Figure 1 A distance 7 87 inch 200 mm B clamping zone 7 87 inch 200 mm C clamping zone 11 81 inch 300 mm D clamping zone 7 87 inch 200 mm ...

Page 7: ...7 12 AXITEC INSTALLATION USA 170727 3 2 72 CELL MODULES A distance 11 42 inch 290 mm B clamping zone 7 87 inch 200 mm ...

Page 8: ...e mounted on the roof of a building The modules are supported parallel to the surface of the building roof To prevent wiring damage and to allow air to circulate behind the module clearance between the module frames and surface of the roof is required The standoff minimum height is 3 9 inch about 100 mm refer to Figure 2 If other mounting means are employed this may affect the listing for fire cla...

Page 9: ...grounded in accordance with the appropriate respective National Electrical Code Proper grounding is achieved by bounding the module frame and all metallic structural members together continuously using a suitable grounding conductor The grounding conductor or strap may be copper copper alloy or other material acceptable for use as an electrical conductor per respective National Electrical Codes Th...

Page 10: ...and temperature rating of the conductors to be used Size 12AWG Type Tinned fine copper strands according to VDE 0295 IEC60228 class 5 Temperature rating 40 C up to 125 C 4 3 ARRAY WIRING Use copper wire only Cu only that is sunlight resistant and is insulated to withstand the maximum possible system open circuit voltage For use with non metallic wiring systems only For field connections use minimu...

Page 11: ...and VOC marked on this module should be multiplied by a factor of 1 25 when determining component voltage ratings conductor ampacity fuse sizes and size of controls connected to the PV output Refer to Section 690 8 of the National Electrical Code for an additional multiplying factor of 125 percent 80 percent derating which may be applicable 7 2 GENERAL SPECIFICATION Axitec LLC reserves the right t...

Page 12: ...12 12 AXITEC INSTALLATION USA 170727 AXITEC LLC 1819 Underwood BLVD Suite 5 Delran New Jersey 08075 United States of America www axitecsolar us This document is subject to change without notice ...