AXIS T86 Media Converter Switch Series
detectors, etc. When a signal is received the state changes and the input becomes
active (shown under
System Options > Port & Devices > Port Status
).
6-pin terminal blocks for:
• Digital Input/Output
• Power (DC output)
• 0 V DC (-)
Function
Pin
Notes
Specifications
0 V DC (-)
1, 4, 6
0 V DC
DC output
2
Power out
12 V DC, 50 mA
Digital input
0 to max 30 V DC
Configurable
I/O 1 (Input or Output)
3
Digital output (transistor –
open collector)
0 to max 30 V DC,
open drain, 100 mA
Digital input
0 to max 30 V DC
Configurable
I/O 2 (Input or Output)
5
Digital output (transistor –
open collector)
0 to max 30 V DC,
open drain, 100 mA
Network connector dip switches
Important
Always use the default dip switch setting (position B) if the relationship between devices in
the system is not defined.
The camera attaches a particular VLAN tag to all its forwarded multicast packages. The media
converter switch manages how these multicast packages are forwarded between cameras, media
converter switches and other network devices. This especially useful when connecting the camera
and media converter switch to the network in a daisy chain.
By changing the position of the dip switches, each network connector port in the media converter
switch can be configured to manage multicasts in three different ways.