
AXIS T8504–E Outdoor PoE Switch
General information
Authentication password (MD5) = password
Privacy password (DES) = password
Authentication and encryption mode = MD5+DES
SNMPv3 notification
Username = trap
Authentication password = password
Privacy password = password
Authentication and encryption mode = None
For information about how to recover username and password, see
Recover username and password on page 7
.
Recover username and password
Note
The recovery procedure can only be performed from the local LAN and not over Internet or from another IP network. The
user should be able to turn off the unit power when needed. All PoE ports must be disconnected and the unit must have
only one single active Ethernet link.
Note
You might need to add a Telnet client service to Windows 7 or Windows 8.
Note
The entire recovery procedure from unit power on until the username and password is applied must take less than 120 seconds.
1. Disconnect all PoE ports from the unit except for one Ethernet cable. Only one single Ethernet port should be active.
2. Turn off the firewall or enable UDP port 514. Then run IPv4 capable SysLog Server on your computer.
3. Turn off the unit. Wait 10 seconds, then turn the unit back on.
4. A SysLog message appears after approximately 15 seconds. Identify the unit Link-local IPv6 address. A Link-local IPv6
address always starts with FE80.
5. Open a command window on your computer.
-
For Windows 7, go to
Start
and type
cmd
.
-
For Windows 8, press the WINDOWS key and the R key, then type
cmd
.
6. Type
ipconfig
to identify the virtual interface index of Link-local IPv6 address. The virtual interface index is indicated by a
number after
%
. Example: fe80::9c39:db8b:62de:7bv4
%17
7. Prepare the SSH connection by typing
Telnet
[unit Local-link IPv6 address][%virtual interface number]
2525
, but don’t
press ENTER. Example:
Telnet fe80::9c39:db8b:62de:7bv4%17 2525
8. Turn off the unit. Wait 10 seconds, then turn the unit back on.
9. Wait 30 seconds, then press ENTER to start the Telnet session on TCP port 2525.
10. Type
axispasswordrecovery
as username and
axispasswordrecovery
as password. A recovery option to restore the entire
unit to complete factory default including unit network configuration is presented. Press Y to restore the unit. The unit
restarts with default IPv4 192.168.0.254, username
root
and password
pass
.
First-time configuration
When configuring the unit for the first time, follow the steps below:
1. Configure your PC Ethernet network interface to the following IPv4 parameters:
7