AXIS T8504–E Outdoor PoE Switch
SysLog Message
7
Unit configuration changed
is
sent when the unit configuration is
changed.
9
PoE controller reset
is sent when
PoE controller reset occurs.
10
PoE controller has no firmware
is
sent when PoE controller firmware
is erased or is corrupted.
11
Invalid SSH
is sent when a remote
user tries to access the unit by
SSH with incorrect username or
password.
Remote user IPv4/IPv6 address
12
DHCPv4
is sent only the first time
DHCPv4 address is obtained either
by switching from static to DHCPv4
or on power-up.
• Unit hostname
• Unit MAC address
• DHCPv4 address
Message is sent in broadcast format
255.255.255.255 to any SysLog
server connected over LAN and to
SysLog server 1 and 2.
13
DHCPv6
is sent only the first time
DHCPv6 address is obtained either
by switching from static to DHCPv6
or on power-up.
• Unit hostname
• Unit MAC address
• DHCPv6 address
Message is sent in broadcast format
255.255.255.255 to any SysLog
server connected over LAN and to
SysLog server 1 and 2.
14
Invalid VLAN configuration
is sent when the unit upon
power-up detects that current VLAN
configurations prevent the unit from
being managed over the network.
This is possibly due to a faulty new
configuration file being uploaded
to the unit. The unit restores itself
to semi factory default, turns off
VLAN and restores most of its
configuration parameters to factory
default, leaving the unit’s network
IP parameters unchanged. Then the
unit restarts.
Message is sent in broadcast format
255.255.255.255 to any SysLog
server connected over LAN and to
SysLog server 1 and 2.