Axis T8343 User Manual Download Page 1

AXIS T8343 Alert Button

User Manual

Summary of Contents for T8343

Page 1: ...AXIS T8343 Alert Button User Manual ...

Page 2: ...ert Button Table of Contents Solution overview 3 Product overview 4 How to add a device to a Z Wave Network 5 How to test the Z Wave device 6 How to program the Z Wave device 7 Troubleshooting 10 Specifications 11 2 ...

Page 3: ... Z Wave enabled and fully compatible with any Z Wave enabled network The device can be set up in a Z Wave network to communicate directly with other end devices such as lighting controllers or to report directly to a Z Wave controller such as AXIS M5065 PTZ Network Camera 3 ...

Page 4: ...AXIS T8343 Alert Button Product overview Product overview 1 Alert button 2 Rear cover 3 LED indicator 4 Battery compartments 5 Link button 6 Rear cover latch 4 ...

Page 5: ...can also choose to manually add the Z Wave device to a control device Follow the steps below Note For best results exclude the device before starting the inclusion process See Manual exclusion 1 Carefully remove the front cover by pulling the bottom of the front cover You will now see the link button which is used to put the device into learning mode inclusion exclusion 2 Press the link button 3 t...

Page 6: ...when an event occurs The alert button triggers the event for the action rule which then controls other devices such as plugs or dimmers or activates an alarm An alarm is triggered after a short press of the alert button To disarm press for 10 seconds After you have included the device in the network with the Z Wave controller the alert button will send data about its battery power to the controlle...

Page 7: ...n device status changes the unit will check its battery status When the battery level of the unit drops to an unacceptable level the unit will emit a notification report to the nodes in Group 1 When you perform a factory reset the unit will send a Device Reset Locally notification to the node in Group1 Group 2 commands When the Up key is pressed the unit will send a BASIC SET command containing an...

Page 8: ...SION_V2 COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 COMMAND_CLASS_DEVICE_RESET_LOCALLY COMMAND_CLASS_POWERLEVEL COMMAND_CLASS_SECURITY COMMAND_CLASS_SECURITY_2 COMMAND_CLASS_SUPERVISION COMMAND_CLASS_FIRMWARE_UPDATE_MD_V4 COMMAND_CLASS_BATTERY COMMAND_CLASS_WAKE_UP_V2 COMMAND_CLASS_NOTIFICATION_V4 Wake up command class After the detector has been included in a Z Wave network it will go to sleep but wil...

Page 9: ...Alert Button How to program the Z Wave device Minimum wake up interval 600s 10 minutes Maximum wake up interval 86400s 1 day Default wake up interval 14400s 4 hours Wake up interval step seconds 600s 10 minutes 9 ...

Page 10: ...w lists typical problems encountered Symptom Possible Cause Recommendation Cannot perform inclusion and association 1 The device is still connected or has been accidentally included in a previous network 2 The entered PIN code is incorrect 3 The battery has run out of power 4 Battery polarity is reversed 1 Exclude the device before including it again 2 Make sure you entered the correct PIN code 3 ...

Page 11: ...e product page at axis com and locate Support Documentation Specifications Battery AAA Battery x2 Battery life 1 year Range Up to 100m 328 ft line of sight Operating frequency 908 42 MHz US 922 5 MHz JP 868 42 MHz EU FCC ID FU5AC136 Specifications are subject to change without notice measured at 1 trigger per day 11 ...

Page 12: ...User Manual Ver M2 4 AXIS T8343 Alert Button Date November 2018 Axis Communications AB 2017 2019 Part No T10117077 ...

Reviews: