Stand’s

 keyboard 

 

 

 

 

 

turn on / off  the stand, 

 

start/stop movement, 

 

- opening applications (functions) menu,  
- back, 
- during inscribing data used for deleting or used for returning to 
previous position (inscribing PIN code), 

 

- opening main menu,  
- enter (choosing option),  
- during inscribing data adds another position or used for moving 
to next position (inscribing PIN code), 

 

STOP safety button that disconnects motor’s supply,

 

 

 

Knob 

enables  to  move  cursor  up  or  down  (moving  the  knob  right  or  left)  and 

choosing selected option (by pressing the knob).   

 

Knob 

Summary of Contents for STAV20

Page 1: ...Vertical automatic stand STAV User Manual File 2019 01 31 STAV GB...

Page 2: ...3 Technical data 3 4 Stand s keyboard 4 5 Safety rules 5 6 Disposal rules 5 7 Preparing to work 6 8 General operation rules 7 9 Communication interface 8 10 Dimensions 9 11 Applications menu 10 11 1 A...

Page 3: ...nts during e g material resistance testing 2 Complete set Basic set consists 1 Automatic stand 2 Mounting element force meter mounting 3 Power supply 3 Technical data Type Automatic stand STAV Maximal...

Page 4: ...u back during inscribing data used for deleting or used for returning to previous position inscribing PIN code opening main menu enter choosing option during inscribing data adds another position or u...

Page 5: ...specified technical data Do not use the stand if the cover is open Do not use the stand in explosive conditions Do not use the stand in high humidity environment If the stand does not seem to operate...

Page 6: ...etween 0 to 40 C air humidity 20 80 Preparing device to work 1 Put the stand on flat stable surface 2 Carefully mount a force meter to the stand by using supplied mounting element 3 Connect supply to...

Page 7: ...ration rules 1 Make every effort to put the sample safetly and stable before starting measurements 2 During work keep hands in safe distance from sample and moving parts During work keep hands in safe...

Page 8: ...interface The stand is equipped with interfaces RS232C and USB RS232C is used to connect the stand to force meter in order to receive actual force value from the force meter Wireless communication is...

Page 9: ...USER MANUAL 9 _____________________________________________________________________________________________________________________ 10 Dimensions...

Page 10: ...am After selecting Edit user can choose from ID inscribing motion program name Steps inscribing number max 8 of steps actions that are included in one cycle Ref Pos Set setting position from which the...

Page 11: ...me Duration option will show where user can inscribe time in s Sample break automatic detection of sample break Force Condition greater or less and Force value in Newtons options will show up Position...

Page 12: ...used when user wants to set motion steps based on force meter movement up and down 12 Main menu After turning on the stand following menu appears User by turning knob changes selected position on the...

Page 13: ...Min Peak minimal peak value Overload Set max force which can act on force meter Send Start enables to send start command to force meter by key on stand Send Zero enables to zero value on force meter I...

Page 14: ...ion POSITION UNKNOWN Reference position is not known Choose in main menu Reference position NO SUPPLY Stand engine supply off security STOP buton pressed Turn off STOP button If the button is off then...

Page 15: ...tand STAV500 marked with comply with the following Directive 2004 108 EWG EWG electromagnetic compatibility and harmonized norms EN 61000 6 3 2008 A1 2012 EN 61000 4 3 2007 A1 2008 A2 2011 Informacje...

Page 16: ...16 USER MANUAL _____________________________________________________________________________________________________________________ Notes...

Reviews: