AXIS Q8685-E PTZ Network Camera
• Use cable gaskets or cable glands that match both the cable hole and the cable area
For information about accessories, such as cable gaskets and cable glands that allow for other
cable areas, see
www.axis.com
Operating conditions
This Axis product is intended for indoor and outdoor use.
Temperature
Humidity
Normal: -50 °C to 55 °C (-58 °F to 131 °F)
Maximum (intermittent): 65 °C (149 °F)
Cold start: -40 °C to 55 °C (-40 °F to 131 °F)
10–100% RH (non-condensing)
Power consumption
Typical consumption
Max consumption
16 W
204 W
Important
When using the 22 m (72 ft) AXIS Cable 24 V DC/24–240 V AC with
AXIS Q8685-E 24 V AC/DC, a power supply capable of delivering 400 W is required to
compensate for the power loss in the cable.
NO
NO
NOTICE
TICE
TICE
The typical power consumption values are based on the following:
• Any losses in the power cable disregarded
• No positioning active
• No wiper motor active
• Temperature at 25 °C / 77 °F (all heaters off)
• One H.264 stream at maximum resolution
• MJPEG stream recorded to SD card