AXIS Q8108-R User’s Guide
Page 7
ENGL
IS
H
Pin assignment - I/O connector
LED indicators
Pin
number
Function
Notes
Specifications
1
Output 1
Open collector NPN transistor with the emitter
connected to ground when activated.
Outputs are reserved for developer use.
Max load = 500mA
2
Output 2
3
Input 1
Inactive for voltages less than 1V
Active for voltages more than 3V
Only one input can be programmed via AXIS NVR
manager, see
Power Configuration,
on page 13
Max input = + 30V
4
Input 2
5
Input 3
6
Input 4
7
Input 5
8
Input 6
9
Input 7
10
Input 8
11
5V DC
Power
Can be used to power auxiliary equipment.
Note:
This pin can only be used as power out.
Max load = 250mA
12
GND
Ground
LED Color
Indication
Network
Amber
Link established.
Green
Unlit
Steady for connection to 100 Mbit/s network
For connection to 1Gbit/s network
Power
Green
Power supplied - normal operation.
Green and
Amber
Battery powered
Unlit
Power off
PoE/Link
Green
Steady
Power is being supplied to the camera
Flash slowly
Short circuit
2 flash sequence
Error in PoE connection.
5 flash sequence
Connected units exceed the max load.
6 flash sequence
Connected units in the left or right group
exceed the max load.
Amber
Link established