AXIS P55-E Network Camera Series
4. Put the top cover back in its original position and fasten two diagonally opposite screws
first (torque < 0.7 Nm), and then the other screws.
5. Put the sunshield back in its original position and fasten the screws.
Install the Camera on a Bracket Mount (sold separately)
WARNING
• Risk of electric shock. The product shall be grounded using a grounding wire. Make sure
both ends of the grounding wire are in contact with their respective grounding surfaces.
NO
NO
NOTICE
TICE
TICE
• To comply with the IP66-rated design of the camera and maintain the IP66 protection,
the supplied RJ45 Push-pull Connector (IP66) shall be used. Alternatively, use the RJ45
IP66-rated cable with premounted connector which is available from your Axis reseller.
Do not remove the plastic network connector shield from the camera.
• Be careful not to damage the network cable when connecting it.
1. Install the bracket (not included) according to the instructions supplied with the bracket.
If drilling is required, make sure to use drill bits, screws and plugs that are appropriate
for the material. See
www.axis.com
for information on available mounting accessories.
2. Secure the camera using the supplied safety wire.
3. Route the network cable and a grounding wire through the holes in the mounting
bracket. Make sure the grounding wire is as short as possible to make the current path
as short as possible.
4. Loosen the grounding screw and remove the washer and cable shoe.
1
3
4
5
2
1.
Network connector – RJ45 Push-pull Connector (IP66)
15
E
N
G
L
IS