AXIS P1375 Network Camera
Specifications
RS485/RS422 connector
Two 2-pin terminal blocks for RS485/RS422 serial interface used to control auxiliary equipment such as pan-tilt devices.
The serial port can be configured to support:
•
Two-wire RS485 half duplex
•
Four-wire RS485 full duplex
•
Two-wire RS422 simplex
•
Four-wire RS422 full duplex point to point communication
Function
Pin
Notes
RS485B alt RS485/422 RX(B)
1
RS485A alt RS485/422 RX(A)
2
RX pair for all modes (combined RX/TX for 2-wire RS485)
RS485/RS422 TX(B)
3
RS485/RS422 TX(A)
4
TX pair for RS422 and 4-wire RS485
Important
The maximum cable length is 30 m (98 ft).
T92G20 connector
Use this connector when you mount the camera in an AXIS T92G20 Outdoor Housing. The connector supplies power to the heater and
the IR illumination in the housing.
21