AXIS P1365 Mk II Network Camera
System Options
It is possible to change the passphrase without reformatting the card. Open
Storage Management
, click
Encrypt
and enter the
old and new passphrases. The passphrase can only be changed when the card is mounted. Changing the passphrase does not
disrupt ongoing recordings.
To disable encryption, unmount the SD card and follow the steps above but clear the
Enable SD card encryption
option. The card
must be formatted and mounted when encryption has been disabled.
Network Share
Network share allows you to add network storage such as a NAS (network-attached storage). The NAS shall be dedicated for
recordings and data from the Axis products connected to the network. For information about reference NAS devices, go to
www.axis.com/products/axis-camera-companion/support-and-documentation
Note
For NAS recommendations see
www.axis.com
To add a network share:
1. Go to
System Options > Storage
.
2. Click
Network Share
.
3. Enter the IP address, DNS or Bonjour name to the host server in the
Host
field.
4. Enter the name of the share in the
Share
field. Sub folders cannot be used.
5. If required, select
The share requires login
and enter the user name and password.
6. Click
Connect
.
To clear all recordings and data from the Axis product’s folder on the designated share, click
Clear
under
Storage Tools
.
To avoid filling the share, it is recommended to remove recordings continuously. Under
Recording Settings
, select
Remove recordings
older than
and select the number of days or weeks.
To stop writing to the share and protect recordings from being removed, select
Lock
under
Recording Settings
.
Ports & Devices
I/O Ports
The Axis product provides two configurable input and output ports for connection of external devices. For information about
how to connect external devices, see
To configure the I/O ports, go to
System Options
>
Ports & Devices
>
I/O Ports
. Each port can function as input or output:
•
Input as Open circuit – The input becomes active when the circuit is grounded by, for example, a REX device. It remains
inactive as long as its normal state equals its current status.
•
Input as Grounded circuit – The input becomes active when the circuit is opened by for example a monitor.
•
Output as Open circuit – The output port is in a non-conductive state when its current status is open circuit. The current
status of an output port can be changed by, for example, an action rule.
•
Output as Grounded circuit – The output port is in a conductive state when its current status is grounded circuit.
COM Port
The Axis product has one RS-485/RS-422 serial port. The port supports the following modes:
•
Generic HTTP
allows the Axis product to receive data and send commands via HTTP.
64