1
2
ø 8
L1
L2
L3
N1
N2
N3
Fig. 5.4
Fig. 5.5
12
CONNECTIONS
Fig. 5.4
1
Open the side of the appliance and locate the terminal
board.
Fig. 5.5
2
Loosen the cable gland and insert the power cable through it.
The label on the side always indicates the type of cable to use
and the cross section. This depends on the appliance voltage and
power consumption (e.g. cable: 4x6 mm
2
H07RNF, see
Fig. 5.3
).
Fig. 5.5
3
Connect the cable conductors following the diagram on the
external plate: ONLY perform the connections indicated
without modifying them. The green earth conductor must be at
least 3 cm longer than the other conductors.
PE (green)
: earth
L1/2/3 (blue/red/black)
: phase
Incorrectly connecting the wires could cause the
terminal board to overheat, leading it to melt and
creating the risk of an electric shock.
4
Check that there is no electric dispersion between phase
and earth. Check the electrical continuity between the outer
casing and the system earth cable. Use a multimeter for these
operations.
5
Close up the side with screws and fix the wire in place by
screwing the cable gland nut.
REPLACING THE POWER SUPPLY CABLE
This must only be done by a qualified, authorised
technician.
The cable must only be replaced with an identical one: the rat-
ings plate always indicates the type of cable to be used and its
cross section (e.g. cable: 4x6 mm
2
H07RNF, see
Fig. 5.3
). The
earthing cable must always be yellow and green.
The connections and colours
are by way of example only.
Please only refer to the dia-
gram on the external plate;
see
Fig. 5.3
Summary of Contents for DIGITAL LINE L06DUS