![Axis BD2P User Manual Download Page 48](http://html.mh-extra.com/html/axis/bd2p/bd2p_user-manual_3038960048.webp)
48
BD/T
USER MANUAL
_____________________________________________________________________________________________________________________
Operation sequence:
Press
MENU
key and choose
thr
pressing
T
key.
The following options are displayed successively:
-
thr oFF
– deactivate the function,
-
thr on
– activate the function,
-
thr Prn
– check last threshold values (press
key several times),
-
thr CFG
– choose
Relays
socket mode:
0
– exit to weighing
1
–
Batching
mode
2
–
Indication
mode.
Choose
thr-on
option using
T
key. The
following options for entering thresholds are
displayed:
-
SEt-0
- go to weighing with signalling threshold
excess,
-
SEt-1
- set lower threshold value,
-
SEt-2
- set upper threshold value,
-
SEt-3
- set zero signalisation threshold.
Using
T
key select
SEt-1
option.
Set lower threshold value using the following keys:
0
- digit increase,
- decimal point,
T
- move to next digit,
MENU
- finish.
Then select
SEt-2
option and enter upper threshold
value.
Choosing
SEt-0
option will cause starting work with
signalisation of exceeding thresholds and zero.
To change
Relays
socket mode use
thr CFG
option.
Default option is
Indication
.
To leave the function, press
MENU
key and then
choose
thr
and
thr oFF
options.
0
g
g