12
USER MANUAL
_____________________________________________________________________________________________________________________
Computer cooperation protocol:
A scale sends data with following settings:
Communication parameters: 8 bits, 1 stop bit, no parity, baud rate 4800bps.
Available orders and scale responses:
initialising signal (data send order):
Computer
→
Scale: S I CR LF (53h 49h 0Dh 0Ah),
Scale
→
Computer: scale response according to description below (16 bytes),
Description of response bytes:
Byte
1
- sign or space
Byte
2
- space
Byte
3
÷
4 - digit or space
Byte
5÷9 - digit, decimal point or space
Byte
10 - digit
Byte
11 - space
Byte
12 - k, l, c, p or space
Byte
13 - g, b, t, c or %
Byte
14 - space
Byte
15 - CR
Byte
16 - LF
scale tarring (calling
→
T
←
key press):
Computer
→
Scale: S T CR LF (53h 54h 0Dh 0Ah),
Scale
→
Computer: without response,
scale turning on / off (calling
I/
key press):
Computer
→
Scale: S S CR LF (53h 53h 0Dh 0Ah),
Scale
→
Computer: without response,
scale zeroing (calling
→
0
←
key press):
Computer
→
Scale: S Z CR LF (53h 5Ah 0Dh 0Ah),
Scale
→
Computer: without response,
entering to special function menu (calling
MENU
key press):
Computer
→
Scale: S F CR LF (53h 46h 0Dh 0Ah),
Scale
→
Computer: without response,
setting low threshold value:
Computer
→
Scale: S L
D1...DN
CR LF (53h 4Ch
D1...DN
0Dh 0Ah)
D1...DN
– threshold value, maximum 8 characters („-” – negative value, digits,
dot – decimal separator), number of digits after dot should be the same as on