52
USER MANUAL
__________________________________________________________________________________________________________________
Operation sequence:
Press
MENU
key and choose
thr
pressing
T
key.
The following options are displayed successively:
-
thr oFF
–
deactivate the function,
-
thr on
–
activate the function,
-
thr Prn
–
check last threshold values (press
key several times),
-
thr CFG
–
choose
Relays
socket mode:
IMPULS - Batching
mode
SIGNAL
–
Indication
mode.
Choose
thr-on
option using
T
key. The
following options for entering thresholds are
displayed:
-
SEt-LO
- set lower threshold value,
-
SEt-HI
- set upper threshold value,
-
SEt-ZEr
- set zero signalisation threshold.
Using
T
key select
SEt-LO
option.
Set lower threshold value using the following
keys:
- digit increase,
- decimal point,
T
- move to next digit,
MENU
- finish.
Then select
SEt-HI
option and enter upper
threshold value.
Choosing
out
option will cause starting work with
signalisation of exceeding thresholds and zero.
To change
Relays
socket mode use
thr CFG
option. Default option is
Indication
.
To leave the function, press
MENU
key and then
choose
thr
and
thr oFF
options.