![Axis 250S Blade Installation Manual Download Page 5](http://html.mh-extra.com/html/axis/250s-blade/250s-blade_installation-manual_3039779005.webp)
5
AXIS 250S Blade - Rack Solution Installation Guide
AXIS 250S Blade
Switch
- for selecting 75 ohm video
termination (for BNC). By default set to
ON.
Bus Connector -
connected to the I/O
terminal block connector at the back of the
rack.
Axis Video Server Rack
The I/O Terminal Block
- the physical interface to a relay switch output and four digital
photo-coupled inputs; also providing an RS-485 interface and an RS-232 serial
connection.
Network Connector
- Axis blade video servers are designed for 10 Mbps Ethernet /100
Mbps Fast Ethernet networks and connect to the network via a standard RJ 45 connector.
DC + Power 12VDC Power (output)
- This connector can drive the photo coupler inputs or
other equipment such as an IR-sensor. A maximum current (for all pins) of 1000mA can be
sourced from the DC output.
Power Connector
- Input power: 100-240 VAC, 50-60 Hz, 1.6A
1
2
1
2
I/O Terminal
Blocks
Network
Connectors
DC-Power
(GND)
Power
Connector
DC+Power