background image

AXIS M50 PTZ Camera Series

Troubleshooting

Note

When you upgrade the device with the latest firmware in the active track, the product receives the latest functionality
available. Always read the upgrade instructions and release notes available with each new release before you upgrade the
firmware. To find the latest firmware and the release notes, go to

axis.com/support/firmware

.

1. Download the firmware file to your computer, available free of charge at

axis.com/support/firmware

.

2. Log in to the device as an administrator.

3. Go to

Maintenance > Firmware upgrade

and click

Upgrade

.

When the upgrade has finished, the product restarts automatically.

You can use AXIS Device Manager to upgrade multiple devices at the same time. Find out more at

axis.com/products/axis-device-manager

.

Technical issues, clues, and solutions

If you can’t find what you’re looking for here, try the troubleshooting section at

axis.com/support

.

Problems upgrading the firmware

Firmware upgrade failure

If the firmware upgrade fails, the device reloads the previous firmware. The most common reason
is that the wrong firmware file has been uploaded. Check that the name of the firmware file
corresponds to your device and try again.

Problems after firmware
upgrade

If you experience problems after a firmware upgrade, roll back to the previously installed version
from the

Maintenance

page.

Problems setting the IP address

The device is located on a
different subnet

If the IP address intended for the device and the IP address of the computer used to access the
device are located on different subnets, you cannot set the IP address. Contact your network
administrator to obtain an IP address.

The IP address is being used
by another device

Disconnect the Axis device from the network. Run the ping command (in a Command/DOS window,
type

ping

and the IP address of the device):

• If you receive:

Reply from <IP address>:

bytes=32; time=10...

this means that the IP address may already be in use by another device on the network.
Obtain a new IP address from the network administrator and reinstall the device.

• If you receive:

Request timed out

, this means that the IP address is available

for use with the Axis device. Check all cabling and reinstall the device.

Possible IP address conflict
with another device on the
same subnet

The static IP address in the Axis device is used before the DHCP server sets a dynamic address.
This means that if the same default static IP address is also used by another device, there may
be problems accessing the device.

The device can’t be accessed from a browser

Can’t log in

When HTTPS is enabled, ensure that the correct protocol (HTTP or HTTPS) is used when attempting
to log in. You may need to manually type

http

or

https

in the browser’s address field.

If the password for the user root is lost, the device must be reset to the factory default settings.
See

Reset to factory default settings on page 24

.

25

Summary of Contents for 02345-001

Page 1: ...AXIS M50 PTZ Camera Series AXIS M5074 PTZ Camera AXIS M5075 PTZ Camera User Manual...

Page 2: ...aning recommendations 17 Learn more 18 Capture modes 18 Privacy masks 18 Overlays 19 Pan tilt and zoom PTZ 19 Streaming and storage 19 Applications 22 Troubleshooting 24 Reset to factory default setti...

Page 3: ...nter the IP address or host name of the Axis device If you do not know the IP address use AXIS IP Utility or AXIS Device Manager to find the device on the network 2 Enter the username and password If...

Page 4: ...is devices do not impose a password policy as they may be used in various types of installations To protect your data we strongly recommend that you Use a password with at least 8 characters preferabl...

Page 5: ...lly 1 In the live view window if the Zoom slider is visible click Zoom and select Focus 2 Click M and use the slider to set the focus Adjust the focus faster with focus recall areas To save the focus...

Page 6: ...mple fluorescent lighting select Flicker free Select the same frequency as the power line frequency For environments with certain artificial light and bright light for example outdoors with fluorescen...

Page 7: ...ur in low light conditions To reduce motion blur in low light conditions adjust one or more of the following settings in Video Image Exposure Move the Blur noise trade off slider toward Low motion blu...

Page 8: ...at axis com web articles wdr Compensate for barrel distortion Barrel distortion is a phenomenon where straight lines appear increasingly bent closer to the edges of the frame A wide field of view ofte...

Page 9: ...t of the image contains enough pixels to for example recognize the face of a person you can use the pixel counter 1 Go to Video Image and click 2 Click for Pixel counter 3 In the camera s live view ad...

Page 10: ...t position as a text overlay You can show the pan or tilt position as an overlay in the image 1 Go to Video Overlays and click 2 In the text field type x to show the pan position Type y to show the ti...

Page 11: ...pstream settings are used for both H 264 and H 265 Turn on Dynamic FPS Turn on Dynamic GOP and set a high Upper limit GOP length value Note Most web browsers don t support H 265 decoding and because o...

Page 12: ...1 Go to System Events and add a rule The rule defines when the device will perform certain actions You can set up rules as scheduled recurring or manually triggered 2 Enter a Name 3 Select the Conditi...

Page 13: ...ize and appearance 5 To position the text overlay click and select an option Create a rule 1 Go to System Events and add a rule 2 Type a name for the rule 3 In the list of actions under Overlay text s...

Page 14: ...n the list of conditions under Audio select Audio Detection 4 In the list of actions under Recordings select Record video 5 In the list of storage options select SD_DISK 6 Select the stream profile wh...

Page 15: ...elect Email 7 Type an email address to send the email to 8 The camera doesn t have it s own email server so it has to log into another email server to send mails Fill in the rest of the information ac...

Page 16: ...AXIS M50 PTZ Camera Series Configure your device 5 1 Go to System Stream profiles and select the stream profile 5 2 Select Include audio and turn it on 5 3 Click Save 16...

Page 17: ...ent for example gasoline benzene or acetone 1 Use a can of compressed air to remove any dust or loose dirt from the device 2 If necessary clean the lens with a soft cloth dampened with lukewarm water...

Page 18: ...ote that when using certain capture modes you might not be able to use WDR The lower resolution capture mode may be sampled from the original resolution or it may be cropped out from the original in w...

Page 19: ...iew to a specific position A preset position can consist of the following values Zoom position Focus position manual or automatic Iris position manual or automatic The preset positions can be reached...

Page 20: ...ettings that affect all video streams from the product If you change something in this tab it immediately affects all video streams and recordings The Stream tab contains settings for video streams Yo...

Page 21: ...You are more likely to get better image quality when in scenes with a lot of activity if you use the average bitrate option You can define the total storage required to store the video stream for a s...

Page 22: ...xis com applications To find the user manuals for Axis applications go to help axis com Note Several applications can run at the same time but some applications might not be compatible with each other...

Page 23: ...ch means you don t need a dedicated computer to run the application AXIS People Counter is suitable for any indoor environment like stores libraries or gyms How does estimating occupancy work You can...

Page 24: ...he active track means continuously getting access to all the latest product features while the LTS tracks provide a fixed platform with periodic releases focused mainly on bug fixes and security updat...

Page 25: ...nance page Problems setting the IP address The device is located on a different subnet If the IP address intended for the device and the IP address of the computer used to access the device are locate...

Page 26: ...endering of H 264 images Ensure that your graphics card uses the latest driver You can usually download the latest drivers from the manufacturer s website Color saturation is different in H 264 and Mo...

Page 27: ...JPEG and H 265 video streams simultaneously affects both frame rate and bandwidth Heavy usage of event settings affects the product s CPU load which in turn affects the frame rate Using HTTPS may redu...

Page 28: ...ork connection is unavailable or lost SD card slot NO NO NOTICE TICE TICE Risk of damage to SD card Do not use sharp tools metal objects or excessive force when inserting or removing the SD card Use y...

Page 29: ...actory default settings See Reset to factory default settings on page 24 Connecting to a one click cloud connection O3C service over the internet To connect press and hold the button for about 3 secon...

Page 30: ...User Manual Ver M4 2 AXIS M50 PTZ Camera Series Date June 2022 Axis Communications AB 2022 Part No T10178928...