XF40-Q2901 Explosion-Protected Temperature Alarm Camera
About detectors
6. For detection type
Increase
: Enter the increase rate
(F)
in degrees per seconds in the
Increase rate
fields.
-
The Y-axis
: the degrees in Celsius or Fahrenheit
-
The X-axis
: the increase time in seconds
7. Click
Save
to save your settings or continue to the
Advanced Settings
section to set additional detection conditions.
Advanced Settings
1. In a temperature detection zone: Select
Advanced Settings
to show additional detection settings.
2. Enter an emissivity value (0.50 – 1.00). in the
Emissivity
field. Different materials have different emissivity levels. See
Material Emissivity Table on page 31
.
3. Select
Maximum temperature in the zone
or
Minimum temperature in the zone
as the base for temperature detection:
-
Maximum temperature in zone (C)
: The temperature detection (
Above
/
Below
/
Increase
) will be based on
the maximum temperature in the zone.
-
Minimum temperature in zone (C)
: The temperature detection (
Above
/
Below
/
Increase
) will be based on
the minimum temperature in the zone.
30