Microbolometer Calibration
☐
Show device diagram
Calibration eliminates image flaws (such as vertical bars, phantom images, grainy field of
view, etc.) by equalizing the microbolometer background temperature.
During calibration, the image on the display briefly freezes for up to 1 second.
There are three calibration modes: Manual (M), Semi-Automatic (SA) and Automatic (A).
Select the required mode in the
menu item.
M mode (Manual).
Close the lens cover and press the ON/OFF (5) button briefly.
Open the lens cover after the calibration is completed.