Axion STIM-PRO T-400 Instruction Manual Download Page 14

01

Channel

2 channels with adjustable intensity

02

Intensity

Adjustabl 0 - 80 mA with a load of 500 Ohm 
on each channel

03

Pulse amplitude

Asymmetrical, bi-phasic square pulse

04

Output Voltage

0 - 50 V

05

Power Source

1 pc. 9,0V battery

06

Size

10,2 cm (L) x 6,2 cm (W) x 3,4 cm (H)

07

Weight

150 g incl. battery

08

Frequency

Adjustable from 2 - 150Hz

09

Pulse width

Adjustable from 50 - 300μs

10

Modes

5 TENS modes with adjustable parameters:  
Burst, Normal, Modulation, SD1, SD2.   
P-Mode with 12 pre-defined programs (P) 

11

TENS
Burst mode 

(B)

Burst frequency adjustable from 0.5 - 5Hz
Pulse width adjustable from 50 - 300μs

12

TENS
Normal mode 

(N)

Frequency adjustable from 1 - 150Hz
Pulse width adjustable from 50 - 300μs

13

TENS
Modulation
mode 

(M)

Die Frequenz wird innerhalb von 5 Sekunden 
auf 50% des Einstellwertes gebracht. In den 
folgenden 5 Sekunden wird der Wert wieder 
auf den Einstellwert erhöht.

14

SD1 mode 

(SD1) 

The SD1 (Strength-Duration) mode consists of 
automatic modulation inten-sity and pulse width 
in 40% range. The intensity is always increasing 
while the pulse width is decreasing and vice ver-
sa. The intensity is decreased by 40% while the 
pulse width is increased by 40% in 5 seconds. In 
the next 5 seconds, the intensity is increased by 
40% while the pulse width is decreased by 40%. 
Total cycle time is 10 seconds.

15

SD2 mode 

(SD2) 

As SD1 mode, but with 70% modulation.

16

Program mode 

(P)

Explanation of the programs on p. 22 - 23

17

Low battery  
indicator

A low battery indicator will show up on the 
LCD when the battery is low. Replace battery 
soon.

TECHNICAL DESCRIPTION

14

AXION

EN

Summary of Contents for STIM-PRO T-400

Page 1: ...INSTRUCTION MANUAL STIM PRO T 400 axion GmbH Mollenbachstr 13 71229 Leonberg Germany 2460 V 1 1...

Page 2: ...d back and the pain is felt What is TENS TENS Transcutaneous Electrical Nerve Stimulation uses tiny electrical impulses sent through the skin to the under lying nerves TENS does not cure any physiolog...

Page 3: ...are called endorphins For further details please refer to your doctor Each STIM PRO T 400 is fully equipped with the following standard equipment 1 piece TENS machine 4 pieces Self adhesive electrode...

Page 4: ...ectrodes in the area of the carotid arteries Do not place electrodes on the front of the throat Be careful with stimulation over metal implants User with an implanted electronic device like pacemakers...

Page 5: ...of the machine Regulating the intensity The intensity can be adjusted stepless from 0 80mA by turning the intensity regulators on top of the device Connect the electrodes with the connecting cables Th...

Page 6: ...rams with fixed settings availabe more information regarding the programs on pages 22 23 Regulating the frequency The frequency is adjustable from 1 Hz to 150 Hz The current value is shown on the LCD...

Page 7: ...on the LCD display Timer The device comes with a timer that can be adjusted from 1 to 60 minutes It can also be set to continuous mode The application ends automatically when the timer runs out Progr...

Page 8: ...equency 15 2 Hz wechselnde Frequenz Pulse width 180 s P 05 Alternating frequency Prof Han stimulation Ideal for long term application since the alternating fre quency causes a strong anti habituation...

Page 9: ...umatoid arthritis radiating pain on arms legs feet through modulation suitable for long term use Frequency 50 Hz Pulse width 250 s P 10 Sweep Mode 2 125 Hz In cases of therapy resistant complaints sti...

Page 10: ...Front CONSTRUCTION OF THE DEVICE Back 10 AXION EN...

Page 11: ...time Make sure the power is off Open the battery compartment by sliding down and removing the front cover Remove the battery Insert the new battery Please check that the polarity is correct Close the...

Page 12: ...period of time remove the battery and put it back into the carrying box and keep it in a cool dry place The packed TENS device should be stored and transported under the temperature range of 20 C 60...

Page 13: ...rer of the device There is no stimulation current Check if the electrodes are correctly connected to the same channel and if the intensity is high enough The STIM PRO T 400 device is in compliance wit...

Page 14: ...from 50 300 s 13 TENS Modulation mode M Die Frequenz wird innerhalb von 5 Sekunden auf 50 des Einstellwertes gebracht In den folgenden 5 Sekunden wird der Wert wieder auf den Einstellwert erh ht 14 SD...

Page 15: ...h parts and labor relating thereto The warranty does not apply to damage resulting from improper handling the failure to follow the operating instructions loss or dropping Manufacturer axion GmbH Moll...