SBC81870 Intel
®
Pentium
®
M w/ DDR/VGA/Dual LAN
Trouble Shooting
101
Slot Not Empty:
Indicates that a slot designated as empty by the EISA
Configuration Utility actually contains a board.
System Halted, (Ctrl-Alt-Del) To Reboot:
Indicates the present boot attempt has been aborted and the
system must be rebooted. Press and hold down the CTRL and
ALT keys and press DEL.
Wrong Board in Slot
Please Run Eisa Configuration Utility:
The board ID does not match the ID stored in the EISA non-
volatile memory.
Note: When this error appears, the system will boot in ISA
mode, which allows you to run the EISA Configuration Utility.
Floppy Disk(S) Fail (80):
Unable to reset floppy subsystem.
Floppy Disk(S) Fail (40):
Floppy type dismatch.
Hard Disk(S) Fail (80):
Hard Disk Drive reset failed.
Hard Disk(S) Fail (40):
Hard Disk Drive controller diagnostics failed.
Hard Disk(S) Fail (20):
Hard Disk Drive initialization error.
Hard Disk(S) Fail (10):
Unable to recalibrate fixed disk.
Hard Disk(S) Fail (08):
Sector Verify failed.
Keyboard Is Locked Out – Unlock The Key:
BIOS detect the keyboard is locked. P17 of keyboard controller
is pulled low.