background image

 

 

iii 

Safety Precautions 

 

Before getting started, please read the following important safety precautions. 

1. 

Be  sure  to  ground  yourself  to  prevent  static  charge  when  installing  the  internal 
components. Use a grounding wrist strap and place all electronic components in 
any  static-shielded  devices.  Most  electronic  components  are  sensitive  to  static 
electrical charge. 

2. 

Disconnect  the  power  cord  from  the  IFB112  before  making  any  installation.  Be 
sure both the system and the external devices are turned OFF. Sudden surge of 
power  could  ruin  sensitive  components.  Make  sure  the  IFB112  is  properly 
grounded. 

3. 

Make  sure  the  voltage  of  the  power  source  is  correct  before  connecting  the 
equipment to the power outlet. 

4. 

Turn  OFF  the  system  power  before  cleaning.  Clean  the  system  using  a  cloth 
only. Do not spray any liquid cleaner directly onto the screen.   

5. 

Do  not  leave  this  equipment  in  an  uncontrolled  environment  where  the  storage 
temperature is below -45

 or above 85

. It may damage the equipment. 

6. 

Do not open the system

s back cover. If opening the cover for maintenance is a 

must,  only  a  trained  technician  is  allowed  to  do  so.  Integrated  circuits  on 
computer  boards  are  sensitive  to  static  electricity.  To  avoid  damaging  chips 
from electrostatic discharge, observe the following precautions:  

 

Before  handling  a  board  or  integrated  circuit,  touch  an  unpainted  portion  of 
the  system  unit  chassis  for  a  few  seconds.  This  will  help  to  discharge  any 
static electricity on your body. 

 

W hen  handling  boards  and  components,  wear  a  wrist -grounding  strap, 
available from most electronic component stores . 

 

Summary of Contents for IFB112

Page 1: ...IFB112 Hardware User s Manual...

Page 2: ...usefulness of any information in this document Axiomtek does not make any commitment to update the information in this manual Axiomtek reserves the right to change or revise this document and or produ...

Page 3: ...the power outlet 4 Turn OFF the system power before cleaning Clean the system using a cloth only Do not spray any liquid cleaner directly onto the screen 5 Do not leave this equipment in an uncontroll...

Page 4: ...onent for the computer please read and understand the details below fully When you need to clean the device please rub it with a piece of dry cloth 1 Be cautious of the tiny removable components when...

Page 5: ...bbing alcohol You may moisten a piece of cloth a bit with some water or rubbing alcohol and rub it on the computer Unknown solvents may be harmful to the plastics parts Vacuum cleaner Absorb the dust...

Page 6: ...roper arrangement Trademarks Acknowledgments Axiomtek is a trademark of Axiomtek Co Ltd IBM PC AT PS 2 VGA are trademarks of International Business Machines Corporation Intel and Pentium are registere...

Page 7: ...3 1 2 9 CAN 3 1 2 10 Power 4 1 2 11 Digital I O Relay Console Connector and Pin Definition 4 1 2 12 System LED 8 1 2 13 Wireless 3G GPRS or Wifi 9 1 2 14 Reset Button 9 1 2 15 Operation Temperature 9...

Page 8: ...viii This page is intentionally left blank...

Page 9: ...5 serial ports 1 CAN bus dual LANs 1 DIO Port 2 In 1 Out 1 eMMC 4GB onboard Its vertical din rail form factor makes it easy to install the system in a small cabinet Due to the RISC based architecture...

Page 10: ...Memory 1 x DDR3 256MB SDRAM onboard 1 2 3 Console Port For user setting with debug Connected to DIO terminal Block 1 2 4 LAN LAN 1 LAN 2 10 100Mbps LAN w magnetic isolation protection 1 5KV 10 100Mbp...

Page 11: ...X RX RTS CTS signals RS 232 422 485 Interface select by software COM1 Pin RS 232 RS 422 RS 485 1 TX Data 2 RX TX Data 3 TX RX 4 RX 5 Ground Ground Ground 6 7 RTS 8 CTS 9 1 2 9 CAN DB9 Connector CAN bu...

Page 12: ...or and Pin Definition 2 DI 1DO DI Wet Dry DO Wet DIO Design Specification Digital Input Input Channels 2 source type Input Voltage 0 to 24VDC Digital Input Levels for Dry Contacts Logic level 0 Close...

Page 13: ...sole port IFB112 DIO Terminal Block TB18 Pin No Signal name Meaning 1 COM Plus Common for DIO 2 DI0 Digital Input 3 DI1 4 DO Digital Output 5 COM Minus Common for DIO 6 Relay Relay Out 7 Relay 8 GND C...

Page 14: ...IFB112 User s Manual Introduction 6 Output Circut Digital Input Wiring Dry Contact Wet Contact Note If you are using wet contacts you must connect COM to power...

Page 15: ...112 User s Manual Introduction 7 Digital Output Wiring Relay output with 0 5A 30VDC Relay output There is a very simple application for remote notice that uses relay and lamp as below 1 Normal 2 Warni...

Page 16: ...Relay Relay Out 7 Relay 8 GND For Console Port 9 Console RX 10 Console TX 1 2 12 System LED LED Name Description Color Note Status The LED can help users to judge boot finish or not and the OS can nor...

Page 17: ...49 F 185 F 1 2 17 Humidity 10 95 non condensation 1 2 18 Weight 1kg 1 2 19 Dimensions 31mm W x100mm D x125mm H 1 2 20 System I O Outlet 1 x 9 pin D Sub male connectors COM 1 x CAN bus DB9 connector 1...

Page 18: ...1 setting 1 3 2 JP3 setting Function Setting Copy image to eMMC JP1 1 2 Close Boot to OS IFB122 eMMC Default JP2 3 4 5 6 Close JP2 7 8 11 12 Close Boot to OS IFB122 SD Card JP2 3 4 9 10 Close Function...

Page 19: ...IFB112 User s Manual Introduction 11 1 4 Dimensions The following diagrams show you dimensions and outlines of the IFB112...

Page 20: ...IFB112 User s Manual Introduction 12 1 5 I O Outlets The following figures show you I O outlets on front view and bottom view of the IFB112 Front View Top View Bottom View...

Page 21: ...nual Introduction 13 1 6 Packing List The package bundled with your IFB112 should contain the following items IFB112 System Unit x 1 Din rail Kit x 1 Power terminal block x 1 DIO terminal block x 1 Co...

Page 22: ...IFB112 User s Manual Introduction 14 This page is intentionally left blank...

Page 23: ...Mount that customers can install as below Prepare DIN Mount assembling components screws and bracket ready 2 2 Installing Wall Mounting Opitonal The IFB112 provides Wall Mounting that customers can in...

Page 24: ...IFB112 User s Manual Hardware Installation 16 This page is intentionally left blank...