AIE900-XNX Series U
ser’s Manual
Jumper Setting & Connector
29
3.2
Jumper Setting Summary
Proper jumper settings configure the AIE900-XNX to meet your application purpose. We are
herewith listing a summary table of all jumpers and default settings for onboard devices,
respectively.
PSB905:
Jumper
Functions
Settings
JP1
Recovery Mode
Select
Normal Mode
(Default)
2-3 Close
Recovery Mode
1-2 Close
JP2
AT/ATX Power Mode
Select
ATX Mode
(Default)
1-2
C
lose
AT Mode
2-3
C
lose
Jumper
Functions
Settings
JP4(COM2),
JP5(COM1)
COM1/COM2 or
CAN1/CAN2 Settings
RS-232 (Default)
1-3, 4-6
C
lose
7-9, 8-10
C
lose
RS-422
1-3, 2-4
C
lose
7-9, 8-10
C
lose
RS-485
3-5, 2-4
C
lose
7-9, 8-10
C
lose
CAN
3-5, 4-6
C
lose
9-11, 10-12
C
lose