background image

AIE800-904-FL Series U

ser’s Manual 

 

26 

 

JetPack Flash Method

 

Step 2. 

Please contact our sales or FAE for the latest JetPack. 

 

Untar the files and assemble the root file system with the command below: 

sudo tar xpf imagefilename 

 

 

Note

Please type your full image name instead of imagefilename 

 

Step 3. 

Start flash JetPack:

 

  Plug in the power cable for the AIE800-904-FL to boot up the system and 

enter recovery mode. 

  Press hotkey: Ctl+Alt+T on the host to enter to the terminal window.  

  Change directory to the Linux_for _Tegra folder:  

cd Linux_for_Tegra

 

  Execute the command below on the host to install the image . 

./axiomflash.sh 

 

  The flashing procedure takes approximately 10 minute s or more. Upon 

completion, AIE800-904-FL will automatically reboot, and please set JP1 to 
“Normal Mode” to return to standard mode. 

 

 

Note

Please open the command prompt window on the host system which is 

connected to AIE800-904-FL 

 

Step 4. 

Congratulations, you have successfully installed JetPack on the AIE800-904-FL

 

The default login credentials are:  

Username: nvidia  Password: nvidia 

 

Caution

Running 

$ sudo apt upgrade

 command for NVIDIA JetPack OTA may overwrite 

the  BSP  of  the  AIE  series  platform,  which  can  cause  unexpected  results 

including  losing  I/O  ports.  For  regular  JetPack  updates  or  reflashing,  please 

contact our sales or FAE to get the latest AIE Series JetPack image.    

 

 

Summary of Contents for AIE800-904-FL Series

Page 1: ...AIE800 904 FL Series Embedded System User s Manual...

Page 2: ...or revise this document and or product at any time without notice No part of this document may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechani...

Page 3: ...ake sure the voltage of the power source is correct before connecting it to any power outlet 5 Turn off system power before cleaning Clean the system using a cloth only Do not spray any liquid cleaner...

Page 4: ...ce of a flammable anesthetic mixture with air oxygen or nitrous oxide 4 Mode of operation Continuous Note All I O connectors should be connected with corresponding cables when the system is operating...

Page 5: ...on to components requiring designated products for cleaning as mentioned below Cloth A piece of cloth is the best tool to use when rubbing up a component Although paper towels or tissues can be used o...

Page 6: ...a trademark of Axiomtek Co Ltd IBM PC AT PS 2 VGA are trademarks of International Business Machines Corporation Intel and Pentium are registered trademarks of Intel Corporation NVIDIA and Jetson Jets...

Page 7: ...WARE INSTALLATION 9 2 1 M 2 SSD Installation 10 2 2 Installation of LTE Mini PCIe Module 12 SECTION 3 JUMPER CONNECTOR SETTINGS 15 3 1 Jumper Connector Location 15 3 2 Jumper Setting Summary 17 3 3 Co...

Page 8: ...viii This page is intentionally left blank...

Page 9: ...this ruggedized box PC adopts a fanless and streamlined enclosure made from IP67 rated aluminum die casting and heavy duty steel The AIE800 904 FL is designed to operate under a wide temperature rang...

Page 10: ...er Vision Accelerated Computing and Multimedia It also includes samples documentation and developer tools for both host computer and AIE series and supports higher level SDKs such as DeepStream for st...

Page 11: ...ports 4 antenna openings and comes with two pre installed LTE and two pre installed Wi Fi RF cables before shipment One M12 S Code 4 pos AC in power input 1 2 3 System Specification Watchdog Timer Sup...

Page 12: ...AIE800 904 FL Series User s Manual 4 Introduction 1 3 Dimensions The following diagrams show the dimensions and outlines of the AIE800 904 FL 1 3 1 System Dimensions...

Page 13: ...AIE800 904 FL Series User s Manual Introduction 5 1 3 2 Wall mount Bracket Dimensions...

Page 14: ...AIE800 904 FL Series User s Manual 6 Introduction 1 3 3 VESA mount Bracket Dimensions...

Page 15: ...AIE800 904 FL Series User s Manual Introduction 7 1 4 I O Outlets The following figures show I O outlets on the front of the AIE800 904 FL Top View Bottom View...

Page 16: ...1 Screws pack x 1 Thermal pad kit x 1 Regarding the latest product manual please download them from Axiomtek official website 1 6 Model List AIE800 904 FL Rugged IP67 rated Fanless Edge AI System with...

Page 17: ...contains guidelines for hardware installation Caution Waterproof capability may be affected if the system is improperly disassembled Under such circumstances Axiomtek shall not be held liable for any...

Page 18: ...2 Turn the system upside down to locate and loosen the six screws at the bottom as marked by the red circles in the figure below Then remove the bottom cover Step 3 After removing the bottom cover loc...

Page 19: ...a 30 degree angle up from the horizontal slowly insert the golden finger into the M 2 2242 Key B slot until it is fully inserted in place And secure the M 2 2242 Key B SSD card to the carrier by tigh...

Page 20: ...te and loosen the six screws at the bottom as marked by the red circles in the figure below Then remove the bottom cover Step 3 After removing the bottom cover locate the PCI Express mini card slot on...

Page 21: ...2 3L screw to the marked position Step 6 Find the SMA cables from the adhesive backed cord clip attached to the chassis as shown in the picture below Note The LTE and Wi Fi modules come with different...

Page 22: ...AIE800 904 FL Series User s Manual 14 Hardware Installation This page is intentionally left blank...

Page 23: ...MPER CONNECTOR SETTINGS Proper jumper settings configure the AIE800 904 FL to meet your application purpose This section explains all jumpers and connectors as well as their default settings for onboa...

Page 24: ...per Connector Settings Carrier Board Bottom View Note We strongly recommended that you should not modify any unmentioned jumper setting without Axiomtek FAE s instruction Any modification without inst...

Page 25: ...summary table of all jumpers and default settings for onboard devices respectively Carrier Board Jumper Switch Descriptions Settings JP1 Force Recovery Mode Force Recovery Mode 1 2 Close Normal Mode 2...

Page 26: ...ut Connector M12 X Code 8 pos Female 3 3 1 USB 2 0 Connector C3 Type 4 pos Female 3 3 2 AC Power Jack Connector M12 S Code 4 pos Male 3 3 3 HDMI Connector C3 Type 19 pos Female 3 3 4 Internal Connecto...

Page 27: ...s connectors are compliant with USB 2 0 480Mbps ideal for installing USB peripherals such as the keyboard mouse scanner etc Pin Signal 1 USB_PWR3 2 USB_PN6 3 USB_PP6 4 GND 3 3 3 AC Power Jack Connecto...

Page 28: ...e 3 3 5 Micro USB 2 0 Connector CN1 The CN1 is specifically designed for image flashing only To flash Jetpack please set JP1 to Force Recovery before booting up the system which would force the system...

Page 29: ...M 2 2242 Key B PCIex2 NVM Express SSD for storage use Pin Signal Pin Signal Pin Signal 1 GND 2 3 3V 3 GND 4 3 3V 5 GND 6 NC 7 NC 8 NC 9 NC 10 SSD_LED 11 GND 12 Connector Key 13 Connector Key 14 Connec...

Page 30: ...PERST 51 GND 52 CLKREQ 53 REFCLKN 54 PEWAKE 55 REFCLKP 56 NC 57 GND 58 NC 59 NC 60 NC 61 NC 62 NC 63 NC 64 NC 65 NC 66 NC 67 NC 68 NC 69 NC 70 3 3V 71 GND 72 3 3V 73 GND 74 3 3V 75 GND 3 3 9 SIM Card...

Page 31: ...Pin 128 of NVIDIA Jetson Xavier NX Pin Signal Pin Signal 1 WAKE 2 3 3V 3 No use 4 GND 5 No use 6 1 5V 7 CLKREQ 8 No use 9 GND 10 No use 11 REFCLK 12 No use 13 REFCLK 14 No use 15 GND 16 No use 17 No u...

Page 32: ...AIE800 904 FL Series User s Manual 24 Jumper Connector Settings This page is intentionally left blank...

Page 33: ...he Linux host system is running x86_64 Ubuntu v18 04 please follow the instruction below to install Python first Step 1 Connect the Linux host system to internet Step 2 Install Python with the command...

Page 34: ...n the host to install the image axiomflash sh The flashing procedure takes approximately 10 minutes or more Upon completion AIE800 904 FL will automatically reboot and please set JP1 to Normal Mode to...

Reviews: