Agent200 U
ser’s Manual
Introduction
4
DC input range 9~48V
DC Input has UVP/Reverse protection.
UVP (Under voltage protection)
Reserve protection
Power consumption 9~48VDC, 0.46A~0.11A
0.46A@9V
0.35A@12V
0.11A@48V
DC Terminal Block
Pin
DC Signal Name
1
Power+
2
-
3
Power-
1.2.14 Digital I/O Connector and Pin Definition
4 DI/ 2 DO non isolation
DI: W et/Dry
DO: Sink Type
DIO Design Specification
Digital Input
Input Channels
4,Source type
Input Voltage
0 to 24VDC
Digital Input Levels for Dry
C
ontacts
Logic level 0:Close to GND
Logic level 1:Open
Digital Input Levels for W et
C
ontacts
Logic level 0:+10V to +24V (DI To COM-)
Logic level 1:+3V max.
Digital Output
Output Channels
4,Sink type
Over Current Protection
Max. 200 mA per channel
On-state Voltage
24VDC nominal, open collector to 30V