background image

 

 

 

 

Ⅰ.

GENERAL 

The instrument is a featured , stable and security small hand-held 31/2 digital multimeter. The instrument has the 
function of measuring DCV, ACV, DCA, resistance, temperature, diode positive drop and continuity test, thus it 
is a portable and desirable tool for users. The operation manual includes the relevant safety information and 
warning notice , Please read it carefully and strictly follow all the precautions .   

Ⅱ.

OPEN-CASE INSPECTION 

Open the case and take out the instrument , Please carefully check the below accessories if damaged or missing . 

1.Operation manual     1 pcs 
2.Test leads                  1 pair  
3.Holster                      1 pcs 
Please immediately contact with suppliers if found any missing or damaged . 

III.SAFETY  PRECAUTIONS  

Please note the safety symbols and warning notice. This series meter designed and produced strictly follow the 
electronic measurement safety requirement of GB4793.1 and safety standard of  IEC61010 , meet the standard of 
double insulation ,overvoltage and pollution lever II . Please follow the instructions in this manual to operate the 
meter ,otherwise the performance of instruction protection may be weakened or lost . 

1.Before operation , ensure that the insulation layer of test leads remains unwounded . Do not operate the meter 
if test leads cable or housing insulation is obviously damaged. 
2.When operating the meter , should put the finger on the back of the protection ring on the test leads. 
3.Do not input a voltage over 500V between instrument terminal and ground to avoid electronic shock and the 
damage of the meter . 
4.Be  carefully  to  operate  when  the  measured  voltage  is  higher  than  DC  60V  and  AC  42Vrms  to  prevent 
electronic shock .  
5.Don’t operate instrument if  back-cover is not locked ,it has the risk of electronic shock . 
6.The  measured  signal  shouldn’t  exceed  specified  limited  value  to  prevent  electronic  shock  and  instrument 
damage . 
7. Do not change range when measuring to avoid instrument damage . 
8.Do not test voltage in current terminal . 
9.Use the same nominal specifications of fast fuse to replace the bad  fuse . 
10.Don’t alter internal wiring of the instrument to prevent damage . 

11.When  the  LCD  displays 

 

symbol,  batteries  should  be  replaced  in  time  to  ensure  the  accuracy  of 

measurement . 
12.Do not operate instrument in wet ,hot and high magnetic field. Especially don’t storage instrument in damp 
environment.  
13.Wipe the case with a damp cloth and detergent ,do not use abrasives and alcohol. 
 
 

Summary of Contents for AX-101B

Page 1: ...DIGITAL MULTIMETER AX 101B OPERATION MANUAL...

Page 2: ...e weakened or lost 1 Before operation ensure that the insulation layer of test leads remains unwounded Do not operate the meter if test leads cable or housing insulation is obviously damaged 2 When op...

Page 3: ...function left bottom of LCD displays H Low battery LCD displays symbol Built in battery 9V NEDA1604 6F22 006P Operation temperature 0 40 32 104 Storage temperature 10 50 14 122 Dimensions 150mm 73 5mm...

Page 4: ...est range then select a proper range according to the displaying value If LCD displays 1 it means over range set the knob to a higher range On each range the input impedance of instrument is 10M such...

Page 5: ...rminal 4 2 Set the fuction range knob to resistance range multipled the test leads to the resistance under tested 4 3 Read the measured value from the LCD NOTE To avoid the damage of the instrument be...

Page 6: ...is 6 SQUARE WAVE SIGNAL OUTPUT Set the knob to square wave range the instrument output square wave between V mA and COM NOTE Square wave experiment signal with its rich harmonics can be used as a sim...

Page 7: ...protection 500 V DC or AC peak value Frequency response 40 400 Hz Display sine wave RMS 3 DCA RANGE ACCURACY RESOLUTION 2mA 1 0 2 1 A 20mA 10 A 200mA 1 2 2 100 A 10A 2 0 5 10mA Max input current 10A l...

Page 8: ...m circuit under tested and input jack Set the knob to off gears and turn off the power 2 Loosen the screws on battery case by screwdriver and remove the battery case 3 Take out the old battery and rep...

Reviews: