UMAX141200. Wi-Fi to CAN Converter. Version 1
Page: 21-44
Port
from other clients. This adds versatility to the converter configurations since the same
converter can be used together with both: client and server communication nodes.
The
Remote IP Address
and
Remote Port
are disabled when
Auto Connect to Remote
is set to
No
.
If the user has changed the
Device IP Address
or the
Web Server Port
, the website will be
automatically re-loaded at the new location, see Figure 16.
Figure 16. Website Automatic Relocation
3.5 CAN
Configuration
The main CAN configuration parameters can be configured on the
IP Network/CAN Settings
web page. They are presented in Table 5.
Table 5. Main CAN Configuration Parameters
Configuration
Parameter
Default
Value
Range
Description
Baud Rate
250 kbit/s
{1000, 666.6(6),
500, 250, 125, 100,
83.3(3), 50, 20, 10}
The CAN baud rate
Loopback
Messages
No
{No, Yes}
Specifies, whether the messages received
over the IP network and transmitted on the
CAN bus, are sent back to the IP network.
Setting this value to
Yes
can create an
eternal loop when the same messages are
bounced between two or more converters.
Use with caution.
The CAN filters are set through their own web pages:
CAN ID Range Filters
and
CAN ID Mask
Filters
. If all filters are disabled, all input CAN messages will be output on the IP network.